Skip to main content
Littelfuse Inc. 0467005.NRHF — Circuit Protection

Littelfuse 0467005.NRHF 467 Series Fuse, 5 A, 32 V, 0603

MPN0467005.NRHF
Active

Littelfuse Inc. Series 467 board-mount fuse, 0467005.NRHF, 0603 (1608 metric) surface-mount package, 5 A, 32 V AC/DC, fast blow, 35 A breaking capacity, CSA and UL approved.

$1.3700Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

0467005.NRHF specifications
ParameterValue
Series467
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - AC32 V
Voltage rating - DC32 V
Breaking capacity @ rated voltage35A
Current rating5 A
Response timeFast Blow
Operating temperature-55°C~90°C
Size (Dimension)0.063\" L x 0.032\" W x 0.012\" H (1.60mm x 0.81mm x 0.31mm)
Approval agencyCSA, UL
PackageTape & Reel (TR); Cut Tape (CT)
Melting i2t0.9
Case0603 (1608 Metric)
DC cold resistance0.0089 Ohms

Product details

5 A fast-blow fuse in a 0603 footprint

The Littelfuse 0467005.NRHF is a Series 467 board-mount fuse in a 0603 (1608 metric) surface-mount package. Rated 5 A at 32 V AC/DC, it provides overcurrent protection for circuits where a fast-blow response is needed to limit energy let-through to sensitive downstream components. The 35 A breaking capacity at rated voltage means the fuse safely interrupts fault currents up to that level without rupturing or sustaining an arc — critical for clearing shorts in low-voltage DC rails or secondary-side AC circuits.

Parametric fit and thermal budget

With a DC cold resistance of 0.0089 Ohms, the fuse's own voltage drop at 5 A is under 45 mV — negligible in a 32 V rail, but worth including in a low-voltage (< 5 V) power-path loss calculation. The melting I²t of 0.9 A²s is the energy required to open the fuse element. For a 5 A fuse this is a low value, consistent with the fast-blow characteristic — it lets through less energy than a time-delay fuse of the same current rating, which matters when protecting a load that has a moderate inrush (e.g., a bypass capacitor bank). Operating temperature spans -55°C to 90°C, covering most indoor and outdoor equipment environments. The fuse's current-carrying capability derates above 25°C per the manufacturer's curve — at 85°C ambient the effective rating is roughly 80 % of the 5 A nominal, so a 4 A continuous load is the practical ceiling in a warm enclosure.

Frequently asked questions

What is the breaking capacity of the 0467005.NRHF at 32 V?

The breaking capacity is 35 A at the rated 32 V AC/DC. This is the maximum fault current the fuse can safely interrupt without rupturing.