Littelfuse Inc. 0467001.NRHF — Circuit Protection

Littelfuse 0467001.NRHF 467 Series 1A Fast Blow Fuse, 0603

MPN0467001.NRHF
Active

Littelfuse Inc. 467 Series, Board Mount Fast Blow Fuse, 0467001.NRHF, 1 A, 32 V AC/DC, 0603 (1608 Metric), Surface Mount.

$1.3700Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

0467001.NRHF specifications
ParameterValue
Series467
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - AC32 V
Voltage rating - DC32 V
Breaking capacity @ rated voltage50A
Current rating1 A
Response timeFast Blow
Operating temperature-55°C ~ 90°C
Size (Dimension)0.063\" L x 0.032\" W x 0.012\" H (1.60mm x 0.81mm x 0.31mm)
Approval agencyCSA, UL
PackageTape & Reel (TR) Cut Tape (CT)
Melting i2t0.0212
Case0603 (1608 Metric)
DC cold resistance0.07 Ohms

Product details

Ratings that define the fit

The 0467001.NRHF: Rated 1 A at 32 V AC/DC, this is a low-current, low-voltage fast-blow fuse intended for secondary-side protection on a 24 V or 12 V rail where the available fault current stays under 50 A. The 50 A breaking capacity at rated voltage means the fuse can safely interrupt a short-circuit fault up to that current without rupturing or sustaining an arc — adequate for most low-power DC supplies and battery-backed circuits, but not for high-energy mains-fed rails. Melting I²t of 0.0212 A²s is the energy required to open the element; this value governs coordination with downstream semiconductors and lets you verify that the fuse clears before a protected IC's surge rating is exceeded.

Housed in a standard 0603 (1608 metric) surface-mount package — 1.60 mm x 0.81 mm x 0.31 mm — the footprint matches the common chip resistor/pad layout for this case size, so no special land pattern is needed. Supplied on tape and reel (cut tape available), compatible with high-speed pick-and-place assembly.

Approvals and temperature envelope

Carries CSA and UL recognition — the two primary marks for North American overcurrent protection — confirming the fuse has passed the required interrupting and endurance tests per UL 248-14. Rated for an operating ambient of -55 °C to 90 °C, which covers most indoor and outdoor equipment enclosures; the 90 °C ceiling is the fuse-body temperature, not the PCB hotspot, so derate if the local ambient near the fuse exceeds that figure.

Frequently asked questions

Where can I buy 0467001.NRHF and how is it quoted?

No in-stock or lead-time figures are published here.

What is the DC cold resistance of 0467001.NRHF?

The DC cold resistance is 0.07 Ohms. At 1 A rated current, this produces a voltage drop of 70 mV and a self-heating power dissipation of 70 mW — negligible in most circuits but worth checking if the fuse sits in a low-voltage, high-accuracy sense path.