Skip to main content
Littelfuse Inc. 0451010.NRL — Circuit Protection

0451010.NRL Littelfuse NANO² 451, 10A Fast-Blow SMD Fuse

MPN0451010.NRL
Active

Littelfuse NANO²® 451 series, 0451010.NRL, 10A fast-blow SMD fuse, 125V AC/DC, 35A AC / 50A DC breaking capacity, 2-SMD square end block package, Tape & Reel.

$2.2800Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

0451010.NRL specifications
ParameterValue
SeriesNANO²® 451
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - AC125 V
Voltage rating - DC125 V
Breaking capacity @ rated voltage35A AC, 50A DC
Current rating10 A
Response timeFast Blow
Operating temperature-55°C~125°C
Size (Dimension)0.240\" L x 0.106\" W x 0.106\" H (6.10mm x 2.69mm x 2.69mm)
Approval agencyCSA, PSE, UL
PackageTape & Reel (TR); Cut Tape (CT)
Melting i2t26.46
Case2-SMD, Square End Block
DC cold resistance0.0056 Ohms

Product details

10A fast-blow SMD fuse for board-level protection

The Littelfuse 0451010.NRL is a 10 A fast-blow SMD fuse from the NANO²® 451 series, rated for 125 V AC and 125 V DC. Its fast-blow response clears overcurrents quickly, protecting sensitive downstream components on a PCB. Breaking capacity reaches 35 A AC and 50 A DC at rated voltage, meaning the fuse can safely interrupt a fault up to those levels without rupturing — critical for DC rails where arcs sustain longer.

Housed in a 2-SMD square end block package measuring 6.10 mm x 2.69 mm x 2.69 mm, this fuse is designed for surface-mount assembly. The compact footprint suits dense PCB layouts where through-hole fuses would consume too much real estate. Available on Tape & Reel or Cut Tape, it integrates into standard pick-and-place lines. The DC cold resistance of 0.0056 Ohms keeps voltage drop low in the 10 A path.

Temperature range and approvals

Approvals from CSA, PSE, and UL provide acceptance in North American and Asian markets. The melting I²t of 26.46 A²s gives a measure of the energy needed to open the fuse — useful for coordinating with upstream protection and ensuring the fuse does not nuisance-blow on inrush.

Frequently asked questions

What is the melting I²t of 0451010.NRL?

The melting I²t is 26.46 A²s, which helps coordinate the fuse's response with upstream protection and inrush current events.