Skip to main content
Littelfuse Inc. 045101.6MRL — Circuit Protection

Littelfuse 045101.6MRL NANO² 451 Fuse, 1.6 A, 125 V

MPN045101.6MRL
Active

Littelfuse Inc. NANO²® 451 series, Board Mount (Cartridge Style Excluded) fuse, 045101.6MRL, 1.6 A, 125 VAC/VDC, Fast Blow, 50 A breaking capacity, 2-SMD Square End Block package, Tape & Reel.

$1.4600Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

045101.6MRL specifications
ParameterValue
SeriesNANO²® 451
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - AC125 V
Voltage rating - DC125 V
Breaking capacity @ rated voltage50A
Current rating1.6 A
Response timeFast Blow
Operating temperature-55°C~125°C
Size (Dimension)0.240\" L x 0.106\" W x 0.106\" H (6.10mm x 2.69mm x 2.69mm)
Approval agencyCSA, PSE, UL
PackageTape & Reel (TR); Cut Tape (CT)
Melting i2t1.06
Case2-SMD, Square End Block
DC cold resistance0.058 Ohms

Product details

Board-level overcurrent protection for 1.6 A rails

The Littelfuse 045101.6MRL is a NANO² 451 series surface-mount fuse rated 1.6 A at 125 VAC and 125 VDC, fast-blow response. It protects a 1.6 A load circuit — think a 24 VDC sensor bank, a 5 V logic rail, or a 12 V auxiliary supply on a control board — where the fuse must clear before the downstream regulator or connector exceeds its thermal limit. The 50 A breaking capacity at rated voltage means it safely interrupts a fault current up to that level without rupturing the package or sustaining an arc — sufficient for most secondary-side DC rails and low-power AC branch circuits where the prospective short-circuit current stays under 50 A.

What the ratings mean for the BOM line

The 1.6 A current rating is the continuous current the fuse carries at 25°C ambient without opening. For a 1.6 A load, the fuse operates below its nominal rating with margin; for a 1.5 A load, it sits at 94% of rating — within the typical derating guideline of 75-80% for elevated ambient. The fast-blow characteristic means it opens quickly on a moderate overcurrent, protecting semiconductor junctions that cannot tolerate sustained overload. Melting I²t of 1.06 A²s is the energy required to melt the fuse element. This number governs inrush withstand: a capacitor bank charging through this fuse must stay below 1.06 A²s total energy, or the fuse opens on start-up. It also coordinates with downstream semiconductor fuses or PTCs — the 045101.6MRL should clear before a 2 A fast-blow in series, given the I²t ratio. DC cold resistance of 0.058 Ohms at 25°C produces a voltage drop of 93 mV at rated current — negligible for a 5 V or 12 V rail, but worth checking if the load is a 1.6 A, 1.8 V FPGA core where every millivolt of IR drop matters.

The 2-SMD square end block package measures 6.10 mm long by 2.69 mm wide and 2.69 mm tall — a compact footprint for dense PCB layouts. The square end terminals are soldered to pads on both ends; the fuse body sits above the board, so the solder fillet is visible for AOI inspection. Supplied in Tape & Reel (TR) or Cut Tape (CT) — the TR option suits automated pick-and-place for volume production; CT works for prototype or low-volume builds.

Compliance and sourcing posture

The 045101.6MRL carries CSA, PSE, and UL approvals — accepted in North American, Japanese, and many international regulatory frameworks. UL recognition means the fuse is listed to UL 248-14, the standard for supplementary fuses used in equipment not intended for branch-circuit protection.

Frequently asked questions

Where can I buy 045101.6MRL and how is it quoted?

Submit an RFQ for the specific volume and packaging (Tape & Reel or Cut Tape).

What is the breaking capacity of 045101.6MRL and why does it matter?

The breaking capacity is 50 A at the rated voltage of 125 VAC/125 VDC. This is the maximum fault current the fuse can safely interrupt without rupturing. For a secondary-side DC rail fed from a 100 W supply, the prospective short-circuit current is typically well below 50 A, so this fuse clears safely. For a higher-capacity bus, verify the available fault current stays under 50 A.