KYOCERA AVX Accu-Guard® series, F1206A1R75FWTR, 1.75 A Fast Blow chip fuse in 1206 (3216 metric) SMD package, 32 V DC, 0.035 A²s melting I²t, 50 A breaking capacity, cUL/UL recognized.

$0.3409Ref. price · indicative, final on quote
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

F1206A1R75FWTR specifications
ParameterValue
SeriesAccu-Guard®
Fuse typeBoard Mount (Cartridge Style Excluded)
MountingSurface Mount
Voltage rating - DC32 V
Breaking capacity @ rated voltage50A
Current rating1.75 A
Response timeFast Blow
Operating temperature-55°C~125°C
Size (Dimension)0.122\" L x 0.063\" W x 0.047\" H (3.10mm x 1.60mm x 1.20mm)
Approval agencycUL, UL
PackageTape & Reel (TR)
Melting i2t0.035
Case1206 (3216 Metric)
DC cold resistance0.1 Ohms

Product details

1.75 A Fast Blow chip fuse for dense 32 V DC rails

The F1206A1R75FWTR is a 1.75 A Fast Blow chip fuse from KYOCERA AVX's Accu-Guard® series, housed in a 1206 (3216 metric) SMD package. It is designed for overcurrent protection on DC power rails up to 32 V, with a breaking capacity of 50 A at rated voltage. The Fast Blow response means it clears quickly on hard shorts, but the 0.035 A²s melting I²t gives it a modest inrush tolerance — enough for bypass capacitors on a 1.75 A rail, but not for a motor start or a large capacitive bank.

Parametric fit: current, voltage, and inrush margin

Rated 1.75 A continuous at 25 °C ambient — derate for elevated board temperature per the Accu-Guard® derating curve. The 32 V DC rating sets the maximum bus voltage; exceeding it risks arc-over after the fuse opens. The 0.1 Ohm DC cold resistance contributes a 175 mV drop at rated current, negligible for most 3.3 V or 5 V rails but worth checking on a 1.8 V supply. Melting I²t of 0.035 A²s is the energy needed to open the fuse element. For a capacitive load, the inrush energy must stay below this value to avoid nuisance opens.

The Accu-Guard® series is a current production line, so the BOM position is stable for new designs and ongoing builds.

Safety approvals and temperature grade

cUL and UL recognition covers branch-circuit protection in listed equipment.

Frequently asked questions

What is the melting I²t and voltage rating of the F1206A1R75FWTR?

Melting I²t is 0.035 A²s, and the voltage rating is 32 V DC. These two numbers together define the fuse's ability to clear a fault without re-striking and its tolerance to inrush energy.