Skip to main content
Analog Devices REF02DSA — Analog & Data Acquisition

REF02DSA 5V Voltage Reference, ±2% Tolerance, 8-SOIC

MPNREF02DSA
End of Life

REF02 series, 5V Voltage Reference, Fixed, 5V output, ±2% tolerance, 21 mA output, 8-SOIC (0.154", 3.90mm Width), Surface Mount, 0°C ~ 70°C.

$2.01Ref. price · indicative, final on quote
Packaging8-SOIC (0.154", 3.90mm Width)
RoHSRoHS non-compliant
SeriesREF02
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

REF02DSA specifications
ParameterValue
SeriesREF02
Output typeFixed
MountingSurface Mount
Reference typeSeries
Voltage - input8V ~ 30V
Voltage - output (Min (Fixed))5V
Output current21 mA
Current - supply2mA
Operating temperature0°C ~ 70°C (TA)
PackageBulk
Tolerance±2%
Case8-SOIC (0.154\", 3.90mm Width)
Noise - 0.1Hz to 10Hz12µVp-p
Temperature coefficient250ppm/°C

Product details

5V fixed reference for ADC bias and regulator rails

The REF02DSA is a 5V fixed-output series voltage reference from the REF02 family, in an 8-SOIC surface-mount package. It delivers a regulated 5V output from an input range of 8V to 30V, with a typical output current of 21 mA and a temperature coefficient of 250 ppm/°C over the 0°C to 70°C commercial range. This part is commonly used to bias the reference input of an ADC, set the regulation point of a downstream linear regulator, or provide a stable 5V rail for analog signal chains in bench instruments, office equipment, and indoor control boards.

21 mA output — how many loads it can drive

The 21 mA output current rating tells you how much total current the reference can supply to all loads on its output pin.

250 ppm/°C drift — what it means for accuracy

The 250 ppm/°C temperature coefficient means the output voltage can shift by up to 250 parts per million for every degree Celsius change in junction temperature.

Note that the part is RoHS non-compliant — it uses lead-bearing solder terminations — which may restrict its use in RoHS-mandated jurisdictions unless an exemption applies.

Frequently asked questions

What is the output current of REF02DSA?

The output current rating is 21 mA. This is the maximum current the reference can source while maintaining regulation. If your total load current exceeds 21 mA, you will need an external buffer amplifier.