Skip to main content
Analog Devices MAX706SCUA — Discrete Semiconductors

MAX706SCUA Power Supply Monitor, 2.93V Threshold

MPNMAX706SCUA
End of Life

Maxim Integrated MAX706SCUA, Power Supply Monitor, Active Low Reset, Push-Pull Output, 140ms Minimum Reset Timeout, 2.93V Threshold, 8-TSSOP/MSOP, 0°C to 70°C.

$3.72Ref. price · indicative, final on quote
Packaging8-TSSOP, 8-MSOP (0.118", 3.00mm Width)
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX706SCUA Technical Specifications
ParameterValue
TypePower Supply Monitor
Mounting typeSurface Mount
Voltage - threshold2.93V
Number of voltages monitored1
Operating temperature0°C ~ 70°C (TA)
ResetActive Low
OutputPush-Pull, Totem Pole
PackageBulk
Reset timeout140ms Minimum
Case8-TSSOP, 8-MSOP (0.118\", 3.00mm Width)

Product details

What the MAX706SCUA does — and what it doesn't

The MAX706SCUA is a single-channel power-supply supervisor that asserts a reset signal when the monitored voltage drops below 2.93 V and holds it active for a minimum of 140 ms after the supply returns above threshold. The reset output is active-low, push-pull. Package is the 8-µMAX.

Temperature grade and environment

Rated for 0°C to 70°C ambient — commercial-grade only. That means indoor, office, or appliance environments where the board temperature stays within that range. Not suitable for automotive under-hood, factory floor, or outdoor telecom enclosures without active cooling that keeps the die below 70°C.

RoHS flag — plan your assembly line

This part is listed as RoHS non-compliant. If your BOM requires lead-free reflow profiles or your end-product must meet RoHS exemption limits, this part will not pass incoming QA. For legacy builds where tin-lead solder is still allowed, it is fine. Verify your assembly house's acceptance before committing the line.

Sourcing and lifecycle reality

That said, the RoHS non-compliance means some authorized channels may have already trimmed stock. We source this part through independent distribution, verified for date-code consistency and marking authenticity.

Frequently asked questions

What is the reset timeout for MAX706SCUA?

The reset timeout is 140 ms minimum. That is the guaranteed hold time after the supply rises above the threshold before the reset pin is released.

What is the equivalent or replacement for MAX706SCUA?

Within the same Maxim supervisor family, the MAX706SCUA is one of several threshold variants. The closest pin-compatible alternatives share the same 8-µMAX package and reset timing but differ in the voltage threshold. For example, the MAX706TCUA has a 3.08 V threshold; the MAX706RCUA has a 2.63 V threshold. Verify your rail voltage before substituting.

Is MAX706SCUA RoHS compliant?

No — this part is listed as RoHS non-compliant. It uses tin-lead solder terminations, not lead-free.