Active production — no last-time-buy on the horizon
The MAX706RCSA+: ROHS3 compliant per the manufacturer listing, which covers the current EU RoHS exemption structure.
This is a Simple Reset/Power-On Reset supervisor monitoring a single voltage rail at a 2.63 V threshold. The 140 ms minimum reset timeout holds the microprocessor in reset long enough for the supply to stabilise after power-up — typical for 3.3 V systems where the supervisor triggers before the core voltage drops out of regulation. Active-low, push-pull output means it drives the reset pin directly without an external pull-up resistor — the output stage sinks or sources current to hold the reset line asserted during the timeout period.
Surface-mount assembly, tube delivery. Not specified for extended industrial or automotive temperature bands.