Skip to main content
Analog Devices MAX6741XKSHD3+ — Discrete Semiconductors

MAX6741XKSHD3+ Multi-Voltage Supervisor, SC-70-5

MPNMAX6741XKSHD3+
End of Life

Analog Devices MAX6741XKSHD3+ Multi-Voltage Supervisor, Active Low Reset, Open Drain Output, SC-70-5, 150ms Reset Timeout, -40°C to +85°C.

$2.74Ref. price · indicative, final on quote
Packaging5-TSSOP, SC-70-5, SOT-353
RoHSROHS3 Compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX6741XKSHD3+ specifications
ParameterValue
TypeMulti-Voltage Supervisor
MountingSurface Mount
Voltage - threshold1.313V, 2.925V
Number of voltages monitored2
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageBulk
Reset timeout150ms Minimum
Case5-TSSOP, SC-70-5, SOT-353

Product details

Dual-rail supervisor in a five-pin SC-70

The MAX6741XKSHD3+ is a multi-voltage supervisor from Analog Devices that monitors two supply rails simultaneously, with thresholds set at 1.313V and 2.925V. It asserts an active-low reset output — open-drain topology — when either monitored voltage drops below its threshold, and holds reset low for a minimum of 150ms after all rails return above threshold.

Housed in a 5-lead SC-70 (also known as SOT-353), the device occupies minimal board area — the 2.0mm × 2.1mm body with 0.65mm pin pitch fits into tight mixed-signal layouts where a supervisor is a late addition to the rail sequence. Surface-mount assembly with no exposed pad simplifies the solder profile; the small body means the part reaches reflow temperature quickly, so the preheat ramp rate matters more than the peak soak.

Frequently asked questions

What does the 150ms reset timeout mean for system startup?

The 150ms minimum reset timeout holds the system in reset for at least 150ms after all monitored rails rise above their thresholds, giving the power supplies, oscillators, and core logic time to stabilize before the processor begins executing code.

Is the MAX6741XKSHD3+ RoHS compliant?

Yes, the part is RoHS3 compliant per Analog Devices' lifecycle data.