Skip to main content
Analog Devices MAX6724UTSVD3-T — Power Management (PMIC / Gate Driver)

MAX6724UTSVD3-T Multi-Voltage Supervisor, 3 Channels

MPNMAX6724UTSVD3-T
End of Life

Analog Devices MAX6724UTSVD3-T multi-voltage supervisor, 3-channel, active-low reset, push-pull output, 1.575V/3.075V/Adj thresholds, 140ms timeout, SOT-23-6, -40°C to +85°C.

$1.84Ref. price · indicative, final on quote
PackagingSOT-23-6
RoHSRoHS non-compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX6724UTSVD3-T specifications
ParameterValue
TypeMulti-Voltage Supervisor
MountingSurface Mount
Voltage - threshold1.575V, 3.075V, Adj
Number of voltages monitored3
Operating temperature-40°C ~ 85°C
ResetActive Low
OutputPush-Pull, Totem Pole
PackageBulk
Reset timeout140ms Minimum
CaseSOT-23-6

Product details

Three-rail voltage supervisor in SOT-23-6

The MAX6724UTSVD3-T is a three-channel multi-voltage supervisor from Analog Devices that monitors up to three independent supply rails with thresholds at 1.575 V, 3.075 V, and one adjustable input. The active-low reset output is push-pull, totem-pole, eliminating the need for an external pull-up resistor on the reset line. A minimum reset timeout of 140 ms holds the system in reset long enough for all rails to stabilise after power-up, which is the standard window for most MCU and FPGA power-on sequences.

Threshold selection and monitoring strategy

The adjustable input lets you set a third threshold with an external resistor divider, so the supervisor can monitor a 1.2 V, 2.5 V, or any other rail the design requires. Because the reset output is active-low push-pull, it drives the reset input of the downstream processor directly without contention — no open-drain bus sharing, no pull-up resistor. This matters when the supervisor is the sole reset source on a board.

It is RoHS non-compliant per the listing, so verify your assembly's exemption policy if the design requires RoHS compliance.

Frequently asked questions

What voltages does the MAX6724UTSVD3-T monitor?

It monitors three rails: fixed thresholds at 1.575 V and 3.075 V, plus one adjustable input that can be set with an external resistor divider for any voltage the design needs.

What is the reset output type on the MAX6724UTSVD3-T?

The reset output is active-low, push-pull (totem-pole). This means it drives the reset line high or low without an external pull-up resistor, unlike open-drain supervisors.