Skip to main content
Analog Devices MAX6715UTZWD3 — Power Management (PMIC / Gate Driver)

MAX6715UTZWD3 Multi-Voltage Supervisor

MPNMAX6715UTZWD3
End of Life

Maxim Integrated MAX6715UTZWD3 Multi-Voltage Supervisor, 2-Channel, Active Low, Open Drain Output, 1.665V/2.313V Threshold, 140ms Reset Timeout, -40°C to 85°C, SOT-23-6.

$2.74Ref. price · indicative, final on quote
PackagingSOT-23-6
RoHSRoHS non-compliant
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX6715UTZWD3 specifications
ParameterValue
TypeMulti-Voltage Supervisor
MountingSurface Mount
Voltage - threshold1.665V, 2.313V
Number of voltages monitored2
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageBulk
Reset timeout140ms Minimum
CaseSOT-23-6

Product details

Package and environment

That covers most factory-floor, outdoor telecom, and automotive cabin applications. The small footprint leaves board space for other monitoring or protection circuitry.

It is not RoHS compliant per the current listing, so verify your assembly house's solder requirements if you are planning a lead-free reflow process.

Frequently asked questions

What is the reset timeout of the MAX6715UTZWD3?

The reset timeout is a minimum of 140ms. After all monitored voltages rise above their thresholds, the reset output remains active for at least 140ms before releasing.

What is the closest pin-compatible alternative to the MAX6715UTZWD3?

The MAX6715 family includes multiple threshold variants in the same SOT-23-6 pinout. For a different voltage pair, check the MAX6715UTZ?D3 series where the '?' encodes the threshold code. The data sheet threshold table lists the available options.

Is the MAX6715UTZWD3 compatible with 3.3V systems?

The MAX6715UTZWD3 monitors rails at 1.665V and 2.313V. If your 3.3V rail needs supervision, this part does not monitor it directly. The open-drain output can be pulled up to 3.3V, so it can signal a 3.3V logic input, but the monitored thresholds are fixed at the values listed.