Open-drain output — pull-up required
The open-drain output can pull the reset line low but cannot drive it high.
It is RoHS non-compliant per the original release, so verify your assembly line's exemption status if you need lead-free solder.

Maxim Integrated MAX6713LEXS, Simple Reset/Power-On Reset, Active Low, Open Drain/Open Collector Output, 140ms Minimum Reset Timeout, 4.63V Threshold, -40°C to 125°C, SC-70-4.
| Parameter | Value |
|---|---|
| Type | Simple Reset/Power-On Reset |
| Mounting | Surface Mount |
| Voltage - threshold | 4.63V |
| Number of voltages monitored | 1 |
| Operating temperature | -40°C ~ 125°C (TA) |
| Reset | Active Low |
| Output | Open Drain or Open Collector |
| Package | Bulk |
| Reset timeout | 140ms Minimum |
| Case | SC-82A, SOT-343 |
The open-drain output can pull the reset line low but cannot drive it high.
It is RoHS non-compliant per the original release, so verify your assembly line's exemption status if you need lead-free solder.
Yes. The open-drain output cannot drive the reset line high; an external pull-up resistor to the supply rail is required.
Maxim's MAX6713 family includes multiple threshold-voltage variants in the same SC-70-4 footprint. For a different trip point, select the variant with the desired threshold — the pinout and function are identical across the family.