Skip to main content
Analog Devices MAX6710PUT+ — Power Management (PMIC / Gate Driver)

MAX6710PUT+ Multi-Voltage Supervisor, 4-Channel, SOT-23-6

MPNMAX6710PUT+
End of Life

Analog Devices MAX6710PUT+ multi-voltage supervisor, 4-channel, active-low open-drain reset, 140ms minimum reset timeout, SOT-23-6 surface-mount package, -40 to 85°C operating range.

$2.11Ref. price · indicative, final on quote
PackagingSOT-23-6
RoHSROHS3 Compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX6710PUT+ specifications
ParameterValue
TypeMulti-Voltage Supervisor
MountingSurface Mount
Voltage - threshold1.67V, 2.78V, Adj, Adj
Number of voltages monitored4
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageBulk
Reset timeout140ms Minimum
CaseSOT-23-6

Product details

Four-rail watchdog in a six-pin package

The MAX6710PUT+: This lets a single SOT-23-6 part cover the core, I/O, and auxiliary voltages on a mixed-logic board without cascading multiple supervisor ICs. When any monitored voltage drops below its threshold, the active-low open-drain reset output asserts and holds for a minimum of 140 ms after all rails recover — long enough for the downstream MCU or FPGA to complete its power-on-reset sequence.

The 140 ms minimum reset timeout is the key number for a board-level debug: if a rail glitches shorter than that, the supervisor holds the system in reset until the supply is stable. On a board with a known brown-out symptom, measuring the reset pin with a scope tells you which rail actually died — the scorch mark on the regulator may be the symptom, not the cause. Operating from -40°C to 85°C, this part covers the industrial temperature band — suitable for outdoor telecom cabinets, factory-floor controllers, and engine-bay electronics where the ambient can swing past the commercial 70°C ceiling.

Frequently asked questions

What does the 140 ms reset timeout mean for my design?

The 140 ms minimum reset timeout ensures that after all monitored voltages rise above their thresholds, the reset output stays low for at least 140 ms. This gives the system clock and core logic time to stabilize before the processor starts executing code — critical for avoiding boot-up glitches on multi-rail designs.

Can the MAX6710PUT+ replace a MAX6710 in the same socket?

The MAX6710PUT+ uses the SOT-23-6 package with the same pinout as the standard MAX6710 variants. If your board already has a MAX6710 in a SOT-23-6 footprint, the MAX6710PUT+ is a drop-in replacement — same thresholds, same reset behavior, same temperature range. Verify the specific threshold version against your BOM before committing.