Skip to main content
Analog Devices MAX6710BUT — Power Management (PMIC / Gate Driver)

MAX6710BUT Multi-Voltage Supervisor, 4-Channel, SOT-23-6

MPNMAX6710BUT
End of Life

Analog Devices MAX6710BUT multi-voltage supervisor, 4-channel, active-low reset, open-drain output, SOT-23-6, -40°C to +85°C.

$2.74Ref. price · indicative, final on quote
PackagingSOT-23-6
RoHSRoHS non-compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX6710BUT specifications
ParameterValue
TypeMulti-Voltage Supervisor
MountingSurface Mount
Voltage - threshold2.32V, 3.08V, 4.63V, Adj
Number of voltages monitored4
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageBulk
Reset timeout140ms Minimum
CaseSOT-23-6

Product details

Four-rail supervision in a SOT-23-6

The MAX6710BUT: Factory-programmed thresholds at 2.32 V, 3.08 V, and 4.63 V cover common logic and I/O voltages, plus an adjustable input for a fourth rail set by an external resistor divider. When any monitored voltage drops below its threshold, the open-drain output pulls low and holds for a minimum 140 ms reset timeout after all rails recover, ensuring the downstream processor sees a clean power-good signal.

Where this supervisor fits on the board

Surface-mount SOT-23-6 footprint — the same land pattern as a standard SOT-23-5 with an extra pin, so the layout is straightforward on a two-layer board. Active-low reset with open-drain output lets multiple supervisors share a common pull-up resistor and wire-OR their reset signals — useful when sequencing several power domains.

RoHS non-compliant per the manufacturer's declaration — verify your assembly's exemption allowance or plan for an alternative if RoHS compliance is required.

Frequently asked questions

What voltages does the MAX6710BUT monitor?

It monitors four channels with factory-set thresholds of 2.32 V, 3.08 V, and 4.63 V, plus one adjustable input that you set with an external resistor divider.

What is the reset timeout duration?

The reset output holds active-low for a minimum of 140 ms after all monitored voltages rise above their thresholds.

Is the MAX6710BUT RoHS compliant?

No — Analog Devices lists it as RoHS non-compliant. Check your assembly's RoHS exemption policy before specifying this part.