Analog Devices MAX6709IUB+ — Power Management (PMIC / Gate Driver)

MAX6709IUB+ Multi-Voltage Supervisor, 4-Channel

MPNMAX6709IUB+
End of Life

Analog Devices MAX6709IUB+, Multi-Voltage Supervisor, 4 channels, active-low open-drain output, thresholds 2.19V/2.93V/Adj/Adj, reset timeout <1ms, -40°C to +85°C, 10-uMAX/uSOP surface-mount package.

$7.19Ref. price · indicative, final on quote
Packaging10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
RoHSROHS3 Compliant
Independent supplier — new & surplus stockAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX6709IUB+ specifications
ParameterValue
TypeMulti-Voltage Supervisor
MountingSurface Mount
Voltage - threshold2.19V, 2.93V, Adj, Adj
Number of voltages monitored4
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageTube
Reset timeout<1ms Minimum
Case10-TFSOP, 10-MSOP (0.118\", 3.00mm Width)

Product details

Four-rail supervisor in a small package

The Analog Devices MAX6709IUB+ is a multi-voltage supervisor that monitors up to four supply rails in a single 10-pin uMAX/uSOP package. Two channels have fixed thresholds at 2.19 V and 2.93 V; the remaining two accept external resistor-divider networks for adjustable thresholds. The active-low reset output is open-drain, rated for <1 ms minimum timeout. Operating temperature spans -40 °C to +85 °C, covering industrial and telecom environments.

Lifecycle and supply position

The MAX6709IUB+ carries an Active lifecycle status and is ROHS3 compliant. No end-of-life notice or last-time-buy window is in effect. For production BOMs, this part is sourced through independent distribution and quoted to order against an RFQ.

Frequently asked questions

What are the exact threshold voltages for each channel on MAX6709IUB+?

Channels 1 and 2 have fixed thresholds of 2.19 V and 2.93 V respectively. Channels 3 and 4 are adjustable via external resistor dividers, allowing custom undervoltage setpoints.

Does MAX6709IUB+ support an active-high reset output?

No, the reset output is active-low only. The open-drain output pulls low when any monitored voltage falls below its threshold.

Where can I buy MAX6709IUB+ with current pricing and availability?

This part is sourced to order through independent distribution. Submit an RFQ for real-time stock and pricing — availability is confirmed at quote time.