Skip to main content
Analog Devices MAX6450UT26L-T — Discrete Semiconductors

MAX6450UT26L-T Multi-Voltage Supervisor, 2.625V Threshold

MPNMAX6450UT26L-T
End of Life

Maxim Integrated MAX6450UT26L-T, Multi-Voltage Supervisor, Active Low Reset, Open Drain Output, 2.625V Fixed + Adj Threshold, 2 Voltages Monitored, 140ms Min Reset Timeout, SOT-23-6, -40°C to 85°C.

$2.01Ref. price · indicative, final on quote
PackagingSOT-23-6
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX6450UT26L-T Technical Specifications
ParameterValue
TypeMulti-Voltage Supervisor
Mounting typeSurface Mount
Voltage - threshold2.625V, Adj
Number of voltages monitored2
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageBulk
Reset timeout140ms Minimum
CaseSOT-23-6

Product details

Two-voltage supervisor in a SOT-23-6 — what it does on the board

The Maxim Integrated MAX6450UT26L-T is a multi-voltage supervisor that monitors two supply rails and asserts an active-low reset when either falls below its threshold. One channel is fixed at 2.625V; the second channel accepts an external resistor divider for an adjustable trip point. The open-drain output holds the reset line low for a minimum of 140ms after all monitored voltages return above threshold — long enough for most MCUs, FPGAs, and DSPs to complete their power-on initialization. The SOT-23-6 package fits tight layouts where board space is at a premium, and the -40°C to 85°C operating range covers industrial control, base station, and outdoor telecom environments.

Open-drain output — wired-OR and level translation

The open-drain output allows multiple supervisors to share a common reset line through a pull-up resistor.

RoHS status — check your assembly line

This part is listed as RoHS non-compliant. For designs that accept tin-lead solder, the MAX6450UT26L-T remains a valid choice.

Frequently asked questions

Is MAX6450UT26L-T RoHS compliant?

No. The MAX6450UT26L-T is listed as RoHS non-compliant. If your BOM mandates lead-free assembly, this part will not pass inspection.

What is the reset timeout of MAX6450UT26L-T?

The reset timeout is a minimum of 140ms. The output holds the reset line low for at least this long after all monitored voltages rise above their thresholds.