Skip to main content
Analog Devices MAX6355LSUT-T — Power Management (PMIC / Gate Driver)

MAX6355LSUT-T Multi-Voltage Supervisor, 3 Channels, SOT-23-6

MPNMAX6355LSUT-T
End of Life

Analog Devices MAX6355LSUT-T multi-voltage supervisor, 3-channel, active-low reset, open-drain output, 100ms minimum reset timeout, SOT-23-6 package, surface mount.

$1.84Ref. price · indicative, final on quote
PackagingSOT-23-6
RoHSRoHS non-compliant
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

MAX6355LSUT-T specifications
ParameterValue
TypeMulti-Voltage Supervisor
MountingSurface Mount
Voltage - threshold2.93V, 4.63V, Adj
Number of voltages monitored3
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageBulk
Reset timeout100ms Minimum
CaseSOT-23-6

Product details

Three-rail monitoring in a single SOT-23-6

The MAX6355LSUT-T is a multi-voltage supervisor from Analog Devices that monitors three supply rails simultaneously — 2.93 V, 4.63 V, and one adjustable threshold — with a single active-low reset output. The open-drain output pulls low when any monitored voltage falls below its threshold and holds the reset state for a minimum of 100 ms after all rails recover, giving the downstream system time to stabilize before releasing the processor. This consolidates three discrete supervisor ICs or resistor-divider comparators into one SOT-23-6 package, saving board area and reducing the component count on a multi-rail power tree.

Active production and sourcing

RoHS non-compliant per the manufacturer's listing — this matters for designs bound by EU RoHS exemptions or legacy BOMs that accept tin-lead finish.

Frequently asked questions

What supply rails does the MAX6355LSUT-T monitor?

It monitors three voltages: 2.93 V (e.g., 3.3 V rail), 4.63 V (e.g., 5 V rail), and one adjustable threshold set by an external resistor divider.

What is the reset timeout of the MAX6355LSUT-T?

The reset output holds low for a minimum of 100 ms after all monitored voltages rise above their thresholds, giving the system time to power up cleanly.

Is the MAX6355LSUT-T RoHS compliant?

Verify your assembly's exemption status before specifying.