Dual-rail supervisor in SOT-23-5
The MAX6352RVUK-T: The reset output remains low for a minimum of 100 ms after both voltages return above threshold, providing a clean power-on reset signal for the downstream processor or FPGA.
Package and temperature grade
Rated for operation from -40°C to +85°C, it covers the industrial temperature range — suitable for factory automation, telecom infrastructure, and outdoor equipment where the ambient temperature stays within this band.
Note that this part is listed as RoHS non-compliant — verify the board-level assembly requirements before specifying it for a lead-free process.