Skip to main content
Analog Devices MAX6328UR24-T — Discrete Semiconductors

MAX6328UR24-T Simple Reset/Power-On Reset, 2.4V Threshold

MPNMAX6328UR24-T
End of Life

Maxim Integrated MAX6328UR24-T, Simple Reset/Power-On Reset, Active Low, Open Drain or Open Collector, 2.4V Threshold, 100ms Minimum Reset Timeout, -40°C to 85°C, SOT-23-3.

$1.32Ref. price · indicative, final on quote
PackagingTO-236-3, SC-59, SOT-23-3
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX6328UR24-T Technical Specifications
ParameterValue
TypeSimple Reset/Power-On Reset
Mounting typeSurface Mount
Voltage - threshold2.4V
Number of voltages monitored1
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageBulk
Reset timeout100ms Minimum
CaseTO-236-3, SC-59, SOT-23-3

Product details

100ms reset timeout — startup sequencing

The 100ms minimum reset timeout gives the power supply and oscillator time to stabilise before the processor starts executing code. If your system has a fast-rising supply and a slow crystal start-up, this part holds the reset long enough to avoid a false boot. The timeout is not programmable — it is a fixed delay, so verify it against your worst-case power-up timing.

Package and mounting

Housed in a SOT-23-3 surface-mount package, this part fits the same footprint as many other single-channel supervisors from Maxim and TI. The three pins are reset output, ground, and VCC — no extra pins for manual reset or watchdog.

Temperature grade and environment

Rated for -40°C to 85°C ambient, this part suits industrial control, outdoor telecom, and automotive cabin environments. Not rated for extended automotive under-hood or military temperature ranges. The industrial temperature grade means it will hold threshold accuracy across the typical factory floor temperature swing.

Frequently asked questions

Is MAX6328UR24-T active or obsolete?

The MAX6328UR24-T is listed as Active in production. No end-of-life notice has been issued, and it remains available for new designs.

What is the reset timeout of MAX6328UR24-T?

The reset timeout is a minimum of 100ms. The output holds low for at least this duration after the supply voltage rises above the 2.4V threshold.

Can I replace MAX6328UR24-T with MAX6328UR24+T?

Yes, the MAX6328UR24+T is the RoHS-compliant (lead-free) version of the same part. The electrical specifications — threshold, timeout, output type, package — are identical. The only difference is the plating finish, so if your BOM requires RoHS compliance, use the +T variant.