Switching speed and signal integrity
Turn-on time is 250 ns maximum, turn-off 350 ns maximum, fast enough for relay-replacement and sample-and-hold circuits in the audio and instrumentation bands. Crosstalk between channels is -59 dB at 1 MHz, and charge injection is 120 pC — both figures matter when switching low-level analog signals without injecting glitches into the signal path. Off-leakage current is 500 pA maximum, preserving accuracy in high-impedance sensor interfaces.
Housed in a 16-SSOP (0.209", 5.30 mm width) package, the MAX4601EAE+ is specified for the industrial temperature range of -40°C to 85°C.