Skip to main content
Analog Devices MAX4435EUK — Logic ICs

MAX4435EUK General Purpose Op-Amp, 150 MHz, 388 V/µs

MPNMAX4435EUK
End of Life

Maxim Integrated MAX4435EUK, General Purpose Amplifier, 1 Circuit, 150 MHz -3dB Bandwidth, 388 V/µs Slew Rate, SOT-23-5, Surface Mount, 4.5 V to 5.5 V Supply.

$1.56Ref. price · indicative, final on quote
PackagingSC-74A, SOT-753
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX4435EUK Technical Specifications
ParameterValue
Mounting typeSurface Mount
Amplifier typeGeneral Purpose
Voltage - input offset1 mV
Voltage - supply span5.5 V
Current - supply15mA
Current - input bias14 µA
Current - output (Channel)65 mA
Operating temperature-40°C ~ 85°C
-3db bandwidth150 MHz
PackageBulk
Slew rate388V/µs
CaseSC-74A, SOT-753
Number of circuits1

Product details

150 MHz, 388 V/µs — what this op-amp delivers

The MAX4435EUK: The 65 mA output current per channel gives it enough drive for video distribution, ADC input buffering, or IF amplifier stages in communications receivers. Input offset voltage is specified at 1 mV, input bias current at 14 µA — adequate for AC-coupled signal paths where DC precision is not the primary concern.

Package and footprint

Housed in a SOT-23-5 package, the supplier device package is SOT-23-5. The 5-pin footprint is common for single op-amps in this bandwidth class. Mounting is surface mount only. The package is listed as Bulk — that refers to the shipping medium, not the device case. The RoHS status is non-compliant, which matters for lead-free assembly lines; verify your solder profile compatibility if the BOM requires RoHS.

Lifecycle and sourcing

The RoHS non-compliance is the sourcing constraint to flag — if your assembly line is RoHS-only, this part requires a waiver or a leaded process step.