Skip to main content
Analog Devices MAX4400ASA — Logic ICs

MAX4400ASA General Purpose Op-Amp, 800 kHz GBW

MPNMAX4400ASA
End of Life

Maxim Integrated MAX4400ASA, General Purpose Amplifier, 1 Circuit Rail-to-Rail Output, 800 kHz Gain Bandwidth, 1V/µs Slew Rate, 2.5V to 5.5V Supply, 8-SOIC Package, -40°C to 125°C.

$1.07Ref. price · indicative, final on quote
Packaging8-SOIC (0.154", 3.90mm Width)
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX4400ASA Technical Specifications
ParameterValue
Output typeRail-to-Rail
Mounting typeSurface Mount
Amplifier typeGeneral Purpose
Voltage - input offset800 µV
Voltage - supply span5.5 V
Current - supply410µA
Current - input bias0.1 pA
Current - output (Channel)30 mA
Operating temperature-40°C ~ 125°C
Gain bandwidth product800 kHz
PackageBulk
Slew rate1V/µs
Case8-SOIC (0.154\", 3.90mm Width)
Number of circuits1

Product details

It delivers an 800 kHz gain-bandwidth product with a 1V/µs slew rate, rail-to-rail output swing, and draws 410 µA supply current. The input bias current is 0.1 pA, and the input offset voltage is 800 µV.

The 800 kHz gain-bandwidth product and 1V/µs slew rate define the usable frequency range for small-signal and large-signal applications respectively. For a unity-gain buffer or active filter, expect clean closed-loop response up to roughly 100 kHz. With 0.1 pA input bias current, the MAX4400ASA loads high-impedance sources like photodiodes or pH probes minimally, preserving signal integrity. The 30 mA output current per channel provides enough drive for ADC inputs or modest loads.

The wide temperature range ensures stable offset and bias performance across thermal extremes without derating.

Frequently asked questions

What is the MAX4400ASA datasheet and where can I find it?

Engineers need full specs (pinout, electrical characteristics) to validate design fit.

Is the MAX4400ASA obsolete or still active?

Lifecycle status is critical for both new design and replacement procurement decisions.

What is the price and availability of the MAX4400ASA?

Sourcing buyers need current price and stock to fill BOM lines and manage costs.

Where can I buy the MAX4400ASA from an authorized distributor?

Transactional intent requires verified supply chain to avoid counterfeits and ensure delivery.

What is a direct replacement or equivalent for the MAX4400ASA?

Maintenance techs and brokers need cross-reference options when the exact part is unavailable.

What are the key specifications of the MAX4400ASA (supply voltage, bandwidth, slew rate)?

Design engineers need to quickly compare with requirements before committing to a BOM.