Dual outputs: one reference, two independent loads
The dual-series architecture means both outputs are derived from the same buried-Zener core, so they track each other over temperature and load. Each output is independently buffered and can source 150 mA. The part is also adjustable up to 6 V via external resistors, though the fixed 5 V version (the -5 suffix) is the most common order.
ROHS3 compliance is confirmed.