Open-drain output — pull-up resistor required
The open-drain output means the DS1813R-5+T&R can only pull the reset line low; it cannot drive it high. You need an external pull-up resistor to VCC (typically 10kΩ to 100kΩ) to hold the reset line high during normal operation. This also lets you wire-OR multiple open-drain reset outputs together, which is useful if you have multiple supervisors or watchdog circuits sharing a common reset line to the processor.
The SOT-23-3 package is a three-pin surface-mount footprint that fits tight layouts and is straightforward for reflow assembly. No exposed pad, no thermal concerns at the low quiescent current these parts draw.