Skip to main content
Analog Devices AD8293G160BRJZ-R7 — Logic ICs

AD8293G160BRJZ-R7 Instrumentation Amp, 500 Hz BW, SOT-23-8

MPNAD8293G160BRJZ-R7
End of Life

Analog Devices AD8293G160BRJZ-R7, single instrumentation amplifier, rail-to-rail output, 500 Hz -3dB bandwidth, 9 µV input offset, 400 pA bias, SOT-23-8 package, -40°C to 85°C.

$2.68Ref. price · indicative, final on quote
PackagingSOT-23-8
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

AD8293G160BRJZ-R7 Technical Specifications
ParameterValue
Output typeRail-to-Rail
Mounting typeSurface Mount
Amplifier typeInstrumentation
Voltage - input offset9 µV
Voltage - supply span5.5 V
Current - supply1mA
Current - input bias400 pA
Current - output (Channel)35 mA
Operating temperature-40°C ~ 85°C
-3db bandwidth500 Hz
PackageTape & Reel (TR); Cut Tape (CT)
CaseSOT-23-8
Number of circuits1

Product details

Precision instrumentation amp in a SOT-23-8

The AD8293G160BRJZ-R7: 500 Hz -3dB bandwidth and 9 µV typical input offset voltage suit DC-precision applications like bridge sensors, thermocouple interfaces, and medical front-ends.

The 500 Hz -3dB bandwidth limits this part to slow signals. ECG, strain-gauge bridges, and thermocouple outputs fit within that passband.

Package and temperature — board-fit realities

Housed in an SOT-23-8, the same footprint as many general-purpose op-amps, so a layout swap from a standard single op-amp is straightforward — just watch the pinout, which is specific to the instrumentation-amp architecture. Surface-mount only; the tape-and-reel option is typical for production volumes, while the cut-tape variant suits prototype or low-volume builds.

Frequently asked questions

What is the AD8293G160BRJZ-R7 used for?

It is a single instrumentation amplifier for precision DC and low-frequency AC signals — ECG, strain-gauge, thermocouple, pressure-sensor, and industrial 4-20 mA loop receiver front-ends. The 500 Hz bandwidth and 9 µV offset make it suited for applications that need gain with high common-mode rejection but do not require fast settling.

Can AD8293G160BRJZ-R7 be used for ECG instrumentation?

Yes. The 1 mA supply current is also appropriate for battery-powered portable ECG monitors.