Specifications

LCE01C302240A Technical Specifications - Column 1
ParameterValue
RoHSRoHS non-compliant
PackageBox
MountingChassis Mount
Coil Voltage230 to 240VAC
Switching Voltage600VAC - Max
Operating temperature25°C to 40°C
LCE01C302240A Technical Specifications - Column 2
ParameterValue
StatusActive
FeaturesAuxiliary Contacts
Coil Power248VA
Contact Form5PST-2NO/3NC (2 Form A, 3 Form B)
Termination StyleScrew Terminal
Contact Rating (Current)30 A

Product details

Siemens LCE01C302240A Lighting Contactor

Contact Configuration and Ratings (LCE01C302240A)

ParameterValue
Contact Form5PST — 2 NO (Form A) / 3 NC (Form B)
Contact Rating30 A
Coil Power248 VA
Coil Voltage230–240 VAC
MountingChassis Mount
Operating Temperature25°C ~ 40°C
EncapsulationBox
FeaturesAuxiliary Contacts
Product StatusActive

The LCE01C302240A is a Siemens Class LCE01C series lighting contactor. The 5-pole contact block provides three NC (Form B) poles and two NO (Form A) poles suitable for lighting load switching. The 248 VA inrush coil power is consistent across the voltage family.

Comparison: Coil Voltage Variants

The reader must qualify each alternate independently. All variants share identical contact arrangement, 30 A rating, chassis mounting, and 248 VA coil power.

MPNCoil VoltageContact FormSimilarity
LCE01C302240A230–240 VAC5PST-2NO/3NC
LCE01C302208A200–208 VAC5PST-2NO/3NC1.0
LCE01C302277A277 VAC5PST-2NO/3NC1.0
LCE01C302600A575–600 VAC5PST-2NO/3NC1.0
LCE01C302024A24 VAC5PST-2NO/3NC1.0
LCE01C302120A115–120 VAC5PST-2NO/3NC1.0
LCE01C302347A347 VAC5PST-2NO/3NC1.0
LCE01C302480A460–480 VAC5PST-2NO/3NC1.0
LCE01C306240A230–240 VAC9PST-6NO/3NC1.0
  • LCE01C302208A — 200–208 VAC coil range; same 5-pole contact form, 248 VA coil power, and chassis mounting.
  • LCE01C302277A — Single-value 277 VAC coil; adds 235.5 VAC must-operate voltage spec; otherwise identical 5-pole arrangement.
  • LCE01C302600A — 575–600 VAC coil range; same contact and mounting specs.
  • LCE01C302024A — 24 VAC coil with 20.4 VAC must-operate spec; same 5-pole, 30 A, chassis-mount configuration.
  • LCE01C302120A — 115–120 VAC coil range; all other specs identical.
  • LCE01C302347A — 347 VAC coil with 295 VAC must-operate spec; identical contact arrangement.
  • LCE01C302480A — 460–480 VAC coil range; all other specs identical.
  • LCE01C306240A — Same 230–240 VAC coil; expands to 9-pole (6 NO / 3 NC) for additional auxiliary contact capacity.

Engineering verification checklist

  • Confirm line voltage falls within the 230–240 VAC coil range before ordering
  • Verify 30 A contact rating meets the specific lighting load ampacity requirements
  • Check that chassis mounting dimensions and hole spacing match the panel cutout
  • Confirm 248 VA coil inrush does not exceed available control-circuit transformer capacity
  • Validate 25°C–40°C operating temperature range is suitable for the intended enclosure ambient
  • Verify that the 5-pole (2 NO / 3 NC) contact arrangement matches the lighting circuit configuration (e.g., multi-wire branch circuits requiring dedicated neutral switching)
  • Confirm auxiliary contact function aligns with the control scheme requirements
  • Review applicable codes for lighting contactor coordination (e.g., NEC Article 210.70 for lighting disconnect requirements)
  • Verify that 248 VA holding current does not cause excessive coil heating in continuous-duty applications

Frequently asked questions

Datasheet and technical review for LCE01C302240A?

Official PDFs beat search snippets. Open the linked document, cite the revision table, and send questions with the MPN line item.

Smallest buy for LCE01C302240A?

Quoted MOQ is usually Evaluation quantities are usually workable—confirm on RFQ.. R&D-friendly splits depend on channel—ask in one line item list.

Catalog value for “Coil Power” (LCE01C302240A)?

**Coil Power** is recorded as **248VA** for LCE01C302240A. If your drawing disagrees, the datasheet wins.

What applications is LCE01C302240A suited for?

Fit depends on electrical, thermal, and mechanical constraints in your BOM—not on generic “industrial” labels. Describe the cabinet role and we map checks to on-page specs.

Second-source options near LCE01C302240A?

Share the non-negotiable parameters (temperature, isolation, connector family, software hooks). We return only rows we can defend with catalog fields.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (2 parts) · columns 2+ sorted by Hub similarity to LCE01C302240A

No extra ranked peers — use featured pair or hub.

Technical resources

Lifecycle: ActiveRoHS: RoHS non-compliant