Skip to main content
LCE01C301120A

LCE01C301120A Contactors (Electromechanical) | siemens

MPNLCE01C301120ACompare · similar
Active · In production

LCE01C301120A (siemens) Contactors (Electromechanical). Package Box; Features Auxiliary Contacts; RoHS RoHS non-compliant. RFQ for MOQ and lead time.

PackagingBox
Volume pricing1+ $681.32000
StockOut of Stock

Specifications

LCE01C301120A Technical Specifications - Column 1
ParameterValue
RoHSRoHS non-compliant
PackageBox
MountingChassis Mount
Coil Voltage115 to 120VAC
Switching Voltage600VAC - Max
Operating temperature25°C to 40°C
LCE01C301120A Technical Specifications - Column 2
ParameterValue
StatusActive
FeaturesAuxiliary Contacts
Coil Power248VA
Contact Form4PST-1NO/3NC (1 Form A, 3 Form B)
Termination StyleScrew Terminal
Contact Rating (Current)30 A

Product details

Siemens LCE01C301120A Electromechanical Contactor

Siemens LCE Series — Lighting Contactor Overview

The LCE01C301120A is a Siemens LCE-series 4-pole lighting contactor with 30 A contact rating and 115–120 VAC coil. It ships as an active catalog item in box packaging. Chassis-mount form factor suits standard panel DIN or back-plane installation in lighting control panels, building automation panels, and industrial control cabinets where 4-pole switching with auxiliary contacts is required.

LCE01C301120A Key Specifications

ParameterValue
Contact Rating (Current)30 A
Contact Form4PST – 1NO/3NC
Coil Voltage115 ~ 120 VAC
Coil Power248 VA
Mounting TypeChassis Mount
Operating Temperature25°C ~ 40°C
FeaturesAuxiliary Contacts
EncapsulationBox
Product StatusActive

Engineering Trade-offs Implied by Stated Specs

  1. The 248 VA inrush coil power requires appropriately sized control-circuit wiring and should drive the selection of any upstream relay or control-transformer capacity in the panel.
  2. The 25°C–40°C operating temperature window is narrow compared with general-purpose contactors; panel thermal management (ventilation, spacing, ambient derating) governs allowable enclosure placement.
  3. Coil heating under sustained energization is a known electromechanical characteristic; the 40°C ceiling constrains use in thermally elevated environments such as unventilated enclosures in warm climates.
  4. The electromechanical construction (versus solid-state) implies contact wear, contact arc management, and mechanical lifecycle considerations that should factor into maintenance scheduling.
  5. Contact current rating applies to resistive or lighting loads; inductive motor loads typically require derating per manufacturer instructions—omitted here but mandatory for motor-branch applications.

Alternate Coil Voltage Options (Same Series)

Readers must qualify each alternate independently against their application voltage before substitution.

MPNCoil VoltageContact FormSimilarity
LCE01C301120A (seed)115 ~ 120 VAC1NO/3NC
LCE01C301208A200 ~ 208 VAC1NO/3NC1.0
LCE01C301240A230 ~ 240 VAC1NO/3NC1.0
LCE01C301480A460 ~ 480 VAC1NO/3NC1.0
LCE01C301600A575 ~ 600 VAC1NO/3NC1.0
LCE01C301024A24 VAC1NO/3NC1.0
LCE01C301277A277 VAC1NO/3NC1.0
LCE01C301347A347 VAC1NO/3NC1.0
LCE01C302120A115 ~ 120 VAC2NO/3NC1.0
  • LCE01C301208A, LCE01C301240A, LCE01C301480A, LCE01C301600A share the same 1NO/3NC contact form and 30 A rating at escalating international mains voltages; substitution requires verifying local supply voltage before use.
  • LCE01C301024A is the sole 24 VAC coil variant, suitable for low-voltage control systems or SELV circuits where other variants require standard mains control.
  • LCE01C301277A and LCE01C301347A are single-voltage (non-range) coils; the lack of a range implies tighter tolerance expectations—verify compatibility with supply variation.
  • LCE01C302120A matches the seed coil voltage but adds a second normally open pole (2NO/3NC); use this where additional NO switching capacity is required without changing control voltage.

Frequently asked questions

Catalog value for “Coil Power” (LCE01C301120A)?

**Coil Power** is recorded as **248VA** for LCE01C301120A. If your drawing disagrees, the datasheet wins.

Second-source options near LCE01C301120A?

Share the non-negotiable parameters (temperature, isolation, connector family, software hooks). We return only rows we can defend with catalog fields.

Datasheet and technical review for LCE01C301120A?

Official PDFs beat search snippets. Open the linked document, cite the revision table, and send questions with the MPN line item.

What does this page list for “Coil Voltage” on LCE01C301120A?

The storefront table shows **Coil Voltage**: 115 to 120VAC. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Smallest buy for LCE01C301120A?

Quoted MOQ is usually Evaluation quantities are usually workable—confirm on RFQ.. R&D-friendly splits depend on channel—ask in one line item list.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (2 parts) · columns 2+ sorted by Hub similarity to LCE01C301120A

No extra ranked peers — use featured pair or hub.

Technical resources

Lifecycle: ActiveRoHS: RoHS non-compliant