Skip to main content
6SL32303YE501CP0

6SL32303YE501CP0 Motor Driver Boards, Modules | siemens

MPN6SL32303YE501CP0Compare · similar
Active · In production

6SL32303YE501CP0 (siemens) Motor Driver Boards, Modules. Type Module; Series SINAMICS G120X; Package Box. RFQ for MOQ and lead time.

PackagingBox
Volume pricing1+ $12,602.33000
StockOut of Stock

Specifications

6SL32303YE501CP0 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
SeriesSINAMICS G120X
PackageBox
Load power160000 W
Load voltage400 to 480 V
Supply voltage380 to 480VAC
For Use With/Related ProductsG120X Series
6SL32303YE501CP0 Technical Specifications - Column 2
ParameterValue
TypeModule
StatusActive
MountingChassis Mount
Motor TypeAC Motor
Output current408 A
Operating temperature20°C to 45°C

Product details

Siemens SINAMICS G120X 6SL32303YE501CP0

Ratings and Physical Specifications (6SL32303YE501CP0)

SpecValue
Input Voltage380–480 V AC
Rated Output Current408 A
Motor Power160 kW
Motor TypeAC Motor
MountingChassis
EncapsulationBox
Operating Temperature20°C to 45°C
Safety ClassFSG (Functional Safety – Safe Stop 0)
SeriesSINAMICS G120X
IP RatingIP20
RoHSRoHS3 Compliant

The SINAMICS G120X series targets pump, fan, and compressor applications in infrastructure and industrial environments where functional safety and basic variable-speed AC drive control are required.

Functional Safety and Certification (6SL32303YE501CP0)

Safety Functionality

The FSG designation confirms Safe Stop 0 (SS0) capability, enabling a controlled motor stop without removing main power. This aligns with IEC 61800-5-2 requirements for safety-related drive systems when integrated with an external safety relay or PLC safety function.

EMC and Compliance

RoHS3 compliance is recorded. EMC filter class (C2 or C3) varies across the product family suffix, distinguishing units suitable for residential/light industrial (C2) versus purely industrial (C3) environments. Panel builders should verify the applicable EMC filter class against the installation site classification.

Panel Integration Notes

Mechanical Mounting

Chassis-mount construction requires a dedicated enclosure or cabinet backplane. The 408 A output current at 160 kW generates substantial heat; thermal management per the specific enclosure sizing guidelines is mandatory for operation within the 45°C ambient ceiling.

System Compatibility

This unit is purpose-built for the G120X series; it does not function as a standalone drive. System integration requires a matching control unit and operator panel (sold separately) to complete the drive architecture.

Family Comparison

The table below compares the seed unit against other 160 kW 380–480 V G120X variants sharing identical electrical ratings. Similarity scores reflect catalog parametric proximity only; qualification is the panel builder's responsibility.

MPNSafety/EMC SuffixSeries LabelSimilarity
6SL32303YE501CP0FSG / C0SINAMICS G120X1.00
6SL32303YE501CF0FSG / C3SINAMICS1.00
6SL32303YE501CB0FSG / C2SINAMICS1.00
6SL32303YE501AP0FSG / C0SINAMICS1.00
6SL32303YE501AB0FSG / C2SINAMICS1.00
6SL32303YE501AF0FSG / C3SINAMICS1.00
6SL32303YE500CP0FSG / C3SINAMICS G120X1.00
6SL32303YE500AP0FSG / C2SINAMICS1.00
6SL32303YE500CF0FSG / C3SINAMICS1.00

All listed variants share the same 408 A output, 380–480 V input range, and 160 kW rating. Differences are confined to the alphanumeric suffix distinguishing EMC filter class (C2 vs. C3) and minor Series label notation. The panel builder must select the EMC filter class appropriate to the installation environment; C2-rated units include integrated filtering for reduced conducted emissions, while C3 units rely on external or downstream filtering.

Frequently asked questions

MOQ rules for 6SL32303YE501CP0 (6SL32303YE501CP0)?

Typical floor: Evaluation quantities are usually workable—confirm on RFQ.. Packaging and factory MOQs can differ; we reconcile on quote.

Are there catalog alternates or second-source candidates for 6SL32303YE501CP0?

We screen on package, interface, headline electricals, and lifecycle cues visible here—not on marketing series names alone, and not as manufacturer interchange approval. Send target rails, loads, and clearance rules for a quote-backed short list.

Typical use cases for 6SL32303YE501CP0?

Application wording stays generic until your constraints are known; the part’s real job is defined by the parameters above.

Catalog value for “Motor Type” (6SL32303YE501CP0)?

**Motor Type** is recorded as **AC Motor** for 6SL32303YE501CP0. If your drawing disagrees, the datasheet wins.

What does this page list for “Load voltage” on 6SL32303YE501CP0?

The storefront table shows **Load voltage**: 400 to 480 V. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 6SL32303YE501CP0

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant