3RV20314PA10 Circuit Breakers | siemens

MPN3RV20314PA10Compare · similar
Active · In production

3RV20314PA10 (siemens) Circuit Breakers. Series 3RV2; Package Bulk; RoHS ROHS3 Compliant. RFQ for MOQ and lead time.

PackagingBulk
Volume pricing1+ $392.88000
StockOut of Stock

Specifications

3RV20314PA10 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
StatusActive
MountingDIN Rail
Actuator TypeRotary
Number of Poles3
Current Rating (Amps)36 A
3RV20314PA10 Technical Specifications - Column 2
ParameterValue
Series3RV2
PackageBulk
Breaker TypeThermal
Approval AgencyCCC, CSA, EAC, IECEx, UL
Voltage Rating - AC690 V

Product details

Siemens 3RV20314PA10 Motor Starter Protector

Product identity and family position

The 3RV20314PA10 belongs to the Siemens 3RV20 series of motor starter protectors (MSPs) with S2 frame designation. The alphanumeric suffix encodes the thermal overload class and current setting window: "PA" denotes Class 10 with a 28–36 A adjustable range, and the trailing "10" indicates the screw-type terminal variant. This bulk-packed unit carries Active product status and supports DIN Rail mounting in three-pole thermal-breaker form.

Key specifications

ParameterValue
Current rating36 A
Overload classClass 10 (28–36 A adjustable)
Breaker typeThermal
Number of poles3
ActuatorRotary
MountingDIN Rail
IlluminationNone
PackageBulk
ApprovalsCCC, CSA, EAC, IECEx, UL

Catalog comparison within the 3RV20314 series

MPNCurrent rangeClassAux contactsApprovals
3RV20314PA10 (primary)28–36 A10NoneCCC, CSA, EAC, IECEx, UL
3RV20314PA1528–36 A101NOATEX, CCC, CE, CSA, EAC, IECEx, UL, VDE
3RV20314PB1028–36 A20NoneCCC, CE, CSA, EAC, UL, VDE
3RV20314EA1022–32 A10NoneCCC, CSA, EAC, IECEx, UL

The PA10 shares its 36 A rating and Class 10 thermal element with PA15, differing in auxiliary contact provision (none versus one normally-open) and the expanded approval set on PA15. PB10 maintains the same current band but escalates to Class 20, which provides longer trip times suitable for motor loads with high inrush but reduced thermal stress. EA10 covers a lower 22–32 A window, while KA10, UA10, WA10, and XA10 span higher current ranges (62–73 A, 32–40 A, 42–52 A, and 49–59 A respectively) with Class 10 thermal elements.

Frequently asked questions

What does this page list for “Breaker Type” on 3RV20314PA10?

The storefront table shows **Breaker Type**: Thermal. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Typical use cases for 3RV20314PA10?

Application wording stays generic until your constraints are known; the part’s real job is defined by the parameters above.

MOQ rules for 3RV20314PA10 (3RV20314PA10)?

Typical floor: Evaluation quantities are usually workable—confirm on RFQ.. Packaging and factory MOQs can differ; we reconcile on quote.

Engineering support on 3RV20314PA10?

Parameter review is grounded in what this page lists; anything beyond that goes through manufacturer FAE channels or your qualification plan.

Stock and scheduling for 3RV20314PA10?

For 3RV20314PA10, treat dates as indicative until confirmed on order. Ships quickly when in stock; otherwise lead time follows distributor or factory lots.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3RV20314PA10

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant