3RV20110BA10

3RV20110BA10 Circuit Breakers | siemens

MPN3RV20110BA10Compare · similar
Active · In production

3RV20110BA10 (siemens) Circuit Breakers. Series 3RV2; Package Bulk; RoHS ROHS3 Compliant. RFQ for MOQ and lead time.

PackagingBulk
Volume pricing1+ $165.86000
StockOut of Stock

Specifications

3RV20110BA10 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
StatusActive
MountingDIN Rail
Actuator TypeRotary
Number of Poles3
Current Rating (Amps)200mA
3RV20110BA10 Technical Specifications - Column 2
ParameterValue
Series3RV2
PackageBulk
Breaker TypeThermal
Approval AgencyATEX, CCC, CSA, EAC, UL
Voltage Rating - AC690 V

Product details

Siemens 3RV20110BA10 Motor Starter Protector

3RV20110BA10 — S00 Size, Screw Terminal, 0.14–0.2 A

The 3RV20110BA10 follows Siemens' S00-format motor protector nomenclature (3RV 20 11 BA 10): three poles, screw terminals, 0.14–0.2 A thermal-trip range. The BA suffix denotes the 0.14–0.2 A band; suffix variants distinguish terminal style and auxiliary contact options within the same frame. This part is classified as thermal-only, whereas several alternates in the same series promote thermal-magnetic trip characteristics.

Siemens S00 3RV2 Series — Key Parameters

Parameter3RV20110BA103RV20110BA153RV20110BA203RV20110BA40
Current Range (A)0.14–0.20.14–0.20.14–0.20.14–0.2
Number of Poles3333
MountingDIN RailDIN RailDIN RailDIN Rail
Breaker TypeThermalThermal MagneticThermal MagneticThermal Magnetic
ActuatorRotaryRotaryRotaryRotary
IlluminationNoneNoneNoneNone
EncapsulationBulkBoxBoxBox
Approval AgenciesATEX, CCC, CSA, EAC, ULATEX, CCC, CE, CSA, EAC, IECEx, UL, VDEATEX, CCC, CE, CSA, EAC, IECEx, UL, VDEATEX, CCC, CE, CSA, EAC, IECEx, UL, VDE

Terminal and Auxiliary Variations in the S00 0.14–0.2 A Band

  • 3RV20110BA15 adds a 1NO/1NC auxiliary contact block; thermal-magnetic trip; packaged in box quantity.
  • 3RV20110BA20 uses spring-clamp terminals instead of screws; thermal-magnetic trip; box packaging.
  • 3RV20110BA40 provides ring-lug terminations; thermal-magnetic trip; box packaging.
  • 3RV20110BA25 combines spring-clamp terminals with a 1NO/1NC auxiliary block; thermal-magnetic.

The screw-terminal BA10 ships in bulk; the box-packaged variants (BA15, BA20, BA25, BA40) list additional CE, IECEx, and VDE certifications absent from the seed record.

Nearby Current-Range Alternatives

MPNCurrent Range (A)Breaker TypeTerminal
3RV20110AA100.11–0.16Thermal MagneticScrew
3RV20110GA100.45–0.63ThermalScrew
3RV20110EA100.28–0.4ThermalScrew
3RV20110JA100.7–1.0ThermalScrew

These share the S00 frame, three-pole layout, and DIN rail mounting but target different motor full-load current bands. The AA10 unit achieves thermal-magnetic trip with the full CE/IECEx/VDE approval set in box packaging.

Frequently asked questions

MOQ rules for 3RV20110BA10 (3RV20110BA10)?

Typical floor: Evaluation quantities are usually workable—confirm on RFQ.. Packaging and factory MOQs can differ; we reconcile on quote.

Engineering support on 3RV20110BA10?

Parameter review is grounded in what this page lists; anything beyond that goes through manufacturer FAE channels or your qualification plan.

What does this page list for “Mounting” on 3RV20110BA10?

The storefront table shows **Mounting**: DIN Rail. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Stock and scheduling for 3RV20110BA10?

For 3RV20110BA10, treat dates as indicative until confirmed on order. Ships quickly when in stock; otherwise lead time follows distributor or factory lots.

Typical use cases for 3RV20110BA10?

Application wording stays generic until your constraints are known; the part’s real job is defined by the parameters above.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3RV20110BA10

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant