3RT20241AB04

3RT20241AB04 Contactors (Electromechanical) | siemens

MPN3RT20241AB04Compare · similar
Active · In production

3RT20241AB04 (siemens) Contactors (Electromechanical). Series SIRIUS; Package Box; Features Auxiliary Contacts. RFQ for MOQ and lead time.

PackagingBox
Volume pricing1+ $135.97000
StockOut of Stock

Specifications

3RT20241AB04 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
StatusActive
FeaturesAuxiliary Contacts
Coil Power65VA
Contact Form3PST-NO (3 Form A)
Release Time16 ms
Termination StyleScrew Terminal
Must Operate Voltage19.2 VAC
Contact Rating (Current)12 A
3RT20241AB04 Technical Specifications - Column 2
ParameterValue
SeriesSIRIUS
PackageBox
MountingChassis Mount, DIN Rail
Coil Voltage24VAC
Operate Time40 ms
Switching Voltage690VAC - Max
Base Product Number3RT2024
Operating temperature25°C to 60°C

Product details

Siemens 3RT20241AB04 Contactors

Cabinet Placement — 3RT2024 S0 Coil and Contacts

The 3RT20241AB04 is a SIRIUS 3RT2 S0 frame contactor intended for DIN rail or chassis mounting in motor-branch or lighting-contact applications. The 24VAC coil requires a suitable control transformer or Class 2 supply in the panel — the coil draws 65VA inrush and 19.2 VAC minimum operate threshold, which shapes upstream control-circuit sizing.

Contact and Coil Specifications

ParameterValue
Base product3RT2024
Contact form3PST-NO (3 Form A main poles)
Contact rating12 A
Coil voltage24 VAC
Coil power (inrush)65 VA
Must-operate voltage19.2 VAC
Operate time40 ms
Operating temperature25°C ~ 60°C
MountingChassis mount / DIN rail
EncapsulationBox

The main pole configuration is listed as 3PST-NO (3 Form A) with two integral auxiliary contacts — one normally open and one normally closed — giving a 2NO/2NC auxiliary function per the title designation.

Family and Voltage Variants

The 3RT2024 series shares the S0 frame, 12 A rating, 65 VA coil power, and DIN rail mounting across all coil voltages. The suffix in each MPN encodes the coil voltage: AB = 24 VAC, AF = 110 VAC, AP = 230 VAC, AV = 400 VAC, AD = 42 VAC. The trailing digit in the part-number position (04 vs 00) differentiates auxiliary contact count — 04 denotes 2NO/2NC; 00 denotes 1NO/1NC.


Comparison — S0 12 A 3RT2024 Family (2NO/2NC Variants)

Readers must qualify alternatives independently against their application voltage and auxiliary contact requirements. Numeric similarity values reflect catalog parametric overlap only.

Spec3RT20241AB04 (seed)3RT20241AF043RT20241AP043RT20241AV04
Coil voltage24 VAC110 VAC230 VAC400 VAC
Must-operate19.2 VAC88 VAC184 VAC320 VAC
Contact rating12 A12 A12 A12 A
Coil power65 VA65 VA65 VA65 VA
Operate time40 ms40 ms40 ms40 ms
MountingDIN / chassisDIN / chassisDIN / chassisDIN / chassis
Similarity1.01.01.0

3RT20241AF04 — Same S0 frame and 65VA coil power at 110 VAC. Maintains 12 A rating and 2NO/2NC auxiliary configuration; differs in must-operate threshold (88 VAC). Suitable for panels fed by 120 VAC control transformers.

3RT20241AP04 — 230 VAC coil variant within the same family. The must-operate voltage shifts to 184 VAC, requiring a 240 VAC control supply. Shares the 65 VA inrush, 40 ms timing, and DIN/chassis mounting.

3RT20241AV04 — 400 VAC coil contactor for use with three-phase 380–415 V control circuits. Must-operate voltage of 320 VAC aligns with standard European control levels. All other specs (12 A, 65 VA, operate time, mounting) are identical.


Engineering Verification Checklist

  • Control-circuit voltage matches coil rating (24 VAC nominal; must-operate 19.2 VAC minimum).
  • Upstream protection and wire sizing appropriate for 12 A main pole current.
  • Panel layout allows DIN rail clearance for box-encapsulated body; operating temperature range is 25°C to 60°C.
  • Auxiliary contact arrangement (2NO/2NC) matches logic requirements for the specific circuit.
  • Supply transformer VA capacity accommodates 65 VA coil inrush without voltage drop below must-operate threshold.
  • Mechanical mounting (DIN rail clip or chassis) verified for installed orientation and vibration environment.
  • All related branch components (overload relays, circuit breakers) are rated for the same 12 A frame size and coordination type.

Frequently asked questions

What is the coil voltage and electrical rating of the 3RT20241AB04?

Engineers must confirm the 24V DC coil and 25A rating match their system voltage and current requirements before purchase.

How do I wire and mount the 3RT20241AB04 contactor?

Proper wiring and DIN rail mounting are critical for compliance with installation standards and equipment safety.

What is the switching capacity and electrical lifespan of this contactor?

Switching capacity determines whether the contactor can handle motor inrush currents and expected operational cycles.

What accessories are compatible with the 3RT20241AB04?

Compatible accessories (surge suppressors, auxiliary contacts, overload relays) are required for complete circuit implementation.

What is the price, MOQ, and lead time for the 3RT20241AB04?

Buyers need accurate pricing and lead time to budget projects and meet procurement schedules.

Is there an equivalent or substitute for the Siemens 3RT20241AB04?

If cost or availability is prohibitive, engineers need cross-reference options to select alternative contactors.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3RT20241AB04

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant