3RH21221AK60

3RH21221AK60 Contactors (Electromechanical) | siemens

MPN3RH21221AK60Compare · similar
Active · In production

3RH21221AK60 (siemens) Contactors (Electromechanical). Series 3RH2; Package Bulk; Features Auxiliary Contacts. RFQ for MOQ and lead time.

PackagingBulk
Volume pricing1+ $93.71000
StockOut of Stock

Specifications

3RH21221AK60 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
StatusActive
FeaturesAuxiliary Contacts
Coil Power37VA
Contact Form3PST-NO (3 Form A)
Release Time15 ms
Base Product Number3RH21221
Operating temperature25°C to 60°C
3RH21221AK60 Technical Specifications - Column 2
ParameterValue
Series3RH2
PackageBulk
MountingChassis Mount, DIN Rail
Coil Voltage120VAC
Operate Time33 ms
Termination StyleScrew Terminal
Must Operate Voltage102 VAC

Product details

Siemens 3RH21221AK60 Auxiliary Contactor Relay

3RH21221 Series Family Notes

The 3RH21221 prefix places this unit within Siemens' 3RH2 auxiliary contactor relay series, sharing the same base part number with all listed alternates. Coil consumption holds constant at 37VA across the family regardless of coil voltage variant.

Contact Form and Circuit Configuration

The seed specifies a 3PST-NO (3 Form A) contact arrangement delivered in bulk packaging with chassis/DIN rail mounting. Several alternates (AK20, AC60, AG60, AU60, AR60, AN60) specify a 4PST-2NO/2NC configuration adding two normally-closed poles, which panel builders should verify against existing wiring diagrams before substitution.

Spec3RH21221AK60 (seed)3RH21221AK203RH21221AP603RH21221AT60
Coil Voltage120VAC120VAC240VAC600VAC
Must Operate102 VAC102 VAC204 VAC510 VAC
Contact Form3PST-NO4PST-2NO/2NC3PST-NO4PST-2NO/2NC
Coil Power37VA37VA37VA37VA
MountingChassis/DINChassis/DINChassis/DINChassis/DIN
Operate Time33 ms33 ms33 ms33 ms
EncapsulationBulkBoxBulkBox
Similarity1.01.01.0

The reader must qualify each alternate independently for their specific installation requirements; similarity scores reflect parametric overlap only.

3RH21221AK20 matches the seed coil voltage (120VAC) and maintains the same must-operate threshold of 102 VAC. The difference lies in contact arrangement—two normally-closed poles replace one normally-open pole, affecting auxiliary circuit wiring topology.

3RH21221AP60 retains the seed contact form (3PST-NO) and bulk packaging but doubles the coil voltage to 240VAC with a corresponding must-operate value of 204 VAC, useful for European mains configurations.

3RH21221AT60 targets higher coil voltage applications at 600VAC nominal with a must-operate of 510 VAC, maintaining the 37VA consumption and 33 ms operate time despite the voltage difference.

Engineering Verification Checklist

  • Confirm coil voltage matches control circuit nominal (120VAC for AK60)
  • Verify must-operate voltage (102 VAC) provides adequate margin with expected supply tolerance
  • Confirm required contact form: 3PST-NO (seed) or 4PST-2NO/2NC (alternates)
  • Verify mounting compatibility with existing DIN rail or chassis cutout
  • Check enclosure temperature rating against 25°C ~ 60°C operating range
  • Confirm auxiliary contact function matches PLC input or indicator circuit requirements
  • Verify packaging preference: bulk (seed, AP60) versus box (alternates)
  • Review coil VA burden against control transformer or power supply capacity when multiple relays are energized simultaneously

Frequently asked questions

Engineering support on 3RH21221AK60?

Parameter review is grounded in what this page lists; anything beyond that goes through manufacturer FAE channels or your qualification plan.

Are there catalog alternates or second-source candidates for 3RH21221AK60?

We screen on package, interface, headline electricals, and lifecycle cues visible here—not on marketing series names alone, and not as manufacturer interchange approval. Send target rails, loads, and clearance rules for a quote-backed short list.

Typical use cases for 3RH21221AK60?

Application wording stays generic until your constraints are known; the part’s real job is defined by the parameters above.

What does this page list for “Must Operate Voltage” on 3RH21221AK60?

The storefront table shows **Must Operate Voltage**: 102 VAC. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

MOQ rules for 3RH21221AK60 (3RH21221AK60)?

Typical floor: Evaluation quantities are usually workable—confirm on RFQ.. Packaging and factory MOQs can differ; we reconcile on quote.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3RH21221AK60

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant