Skip to main content
3LD3330-0TL13

3LD3330-0TL13 Disconnect Switch Components | siemens

MPN3LD3330-0TL13Compare · similar
Active · In production

3LD3330-0TL13 (siemens) Disconnect Switch Components. Type Switch; Series 3LD; Current 40 A. RFQ for MOQ and lead time.

PackagingBox
Volume pricing1+ $227.13000
StockOut of Stock

Specifications

3LD3330-0TL13 Technical Specifications - Column 1
ParameterValue
TypeSwitch
StatusActive
PackageBox
Base Product Number3LD3330
3LD3330-0TL13 Technical Specifications - Column 2
ParameterValue
Series3LD
Current40 A
Voltage690 V

Product details

Siemens 3LD3330-0TL13 Main Switch

Cabinet placement and system integration

The 3LD3330-0TL13 is a front-operated, door-coupling rotary switch suitable for mounting in standard industrial enclosures. The switch provides a visible gap when in the OFF position, meeting the requirements for a disconnecting means in machine control circuits.

Specifications

ParameterValue
Base Product Number3LD3330
Current Rating40 A
Voltage Rating690 V
Poles3-pole + N
EncapsulationBox
Series3LD
Product StatusActive
ManufacturerSiemens

Family variants

The 3LD3330 base covers two pole configurations and two current ratings within the same mechanical package. The TL suffix denotes a 3-pole + neutral arrangement; the TK suffix denotes a 3-pole only. Current ratings for this base include 16 A and 40 A.

Engineering verification checklist

  • Confirm 40 A rating matches calculated circuit load with appropriate derating applied
  • Verify 690 V rating exceeds maximum system voltage at the point of installation
  • Check that 3-pole + N configuration matches the supply system neutral requirement
  • Validate shaft length and coupling mechanism fit for enclosure door operation
  • Confirm panel cutout dimensions match the device mounting requirements
  • Verify that auxiliary contact blocks or accessories, if required, are compatible with the 3LD3330 series mounting pattern
  • Confirm torque values for power terminals per Siemens specification for 40 A terminations
  • Verify that lockout-tagout (LOTO) capability is maintained with the installed handle mechanism

Frequently asked questions

Where does 3LD3330-0TL13 usually earn its keep electrically?

**3LD3330-0TL13** is catalog-class until your constraints say otherwise. Lead with voltage/current class, ambient, and protection philosophy; we answer against those anchors.

Spec drill-down: **Status** for 3LD3330-0TL13?

The row **Status: Active** is what we persist for this SKU. If ERP scrubbers mangled the string, fix upstream—not in paraphrase.

Head-to-head MPN for 3LD3330-0TL13?

The listing carries a compare hint to **3LD2504-0TK53**—use that as a shopping shortlist only. Pin-for-pin still means your CAD librarian checks every net.

How do I order 3LD3330-0TL13 without ambiguity?

Quote **3LD3330-0TL13** exactly as shown under **Siemens 3LD3330-0TL13**—include rev / pack suffixes if your ERP carries them. Typos here are the #1 reason wrong reels land.

Quick sanity check: **Current** on 3LD3330-0TL13?

For **3LD3330-0TL13**, **Current** comes through as **40 A**. Treat anything outside that snapshot as “not on this listing yet.”

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (5 parts) · columns 2+ sorted by Hub similarity to 3LD3330-0TL13

Technical resources

Lifecycle: Active