Temperature range and field-fit realities
The 1.5KE220CA-TP: The wide margin means the TVS can sit near a hot transformer or power resistor without derating prematurely. The device is not rated for power-line protection (the spec explicitly says 'Power Line Protection: No'), so it is intended for signal lines, DC power buses, and low-voltage AC circuits — not mains-voltage surge suppression.