The P6KE12CA-T: The clamping voltage at that peak current is 16.7V max, so a 12V rail sees the spike held under 17V. Reverse standoff voltage is 10.2V typical — the TVS draws negligible leakage below this level, making it suitable for protecting 12V nominal supply lines. Breakdown voltage starts at 11.4V min, ensuring the device does not conduct during normal operation.
Package and deployment context
Through-hole mounting suits point-to-point wiring or prototype boards where rework access is needed. No power line protection (internal construction is not designed for continuous overvoltage) — intended for transient suppression only, not as a shunt regulator.