Siemens 3VA5225-6GC41-0AA0 Molded Case Circuit Breaker

The 3VA5225-6GC41-0AA0 occupies a fixed thermal/magnetic trip position in a four-pole DIN rail configuration within three-phase industrial mains or feeder branches. Catalog records list a 250 A nominal rating and a 65 kA interrupt capacity under UL489 conditions.

Siemens 3VA5225-6GC41-0AA0 Molded Case Circuit Breaker

Functional Position in a Low-Voltage Distribution Panel

The 3VA5225-6GC41-0AA0 occupies a fixed thermal/magnetic trip position in a four-pole DIN rail configuration within three-phase industrial mains or feeder branches. Catalog records list a 250 A nominal rating and a 65 kA interrupt capacity under UL489 conditions.

Key Parameters

SpecificationValue
Series3VA52
Current Rating250 A
Interrupt Rating65 kA
Poles4
MountingDIN Rail
ActuatorLever
IlluminationNone
EncapsulationBox
ApprovalsCCC, CE, CSA, EAC, UL489
RoHS StatusNon-compliant
Product StatusActive

The 3VA52 family encodes breaker size, interrupting rating, and trip unit type through the numeric position of the suffix block. "FTAM" in the title corresponds to the fixed thermal/magnetic trip unit configuration at this frame size.

Catalog Comparison — Similar In-Family Units

Parameter3VA5225-6GC41-0AA03VA5225-6GD41-0AA03VA5225-6GF41-0AA0
Poles444
Current Rating250 A250 A250 A
ActuatorLeverLeverLever
MountingDIN RailDIN RailDIN Rail
IlluminationNoneNoneNone
ApprovalsCCC, CE, CSA, EAC, UL489CCC, CE, CSA, EAC, UL489CCC, CE, CSA, EAC, UL489
  • 3VA5225-6GD41-0AA0 (similarity 0.96): shares the FT__ frame configuration; differs in the trip unit function code (FTFM instead of FTAM).
  • 3VA5225-6GF41-0AA0 (similarity 0.96): retains four-pole and 250 A rating; carries an ATAM trip unit variant, implying a different thermal/magnetic characteristic compared to the FTAM primary.

Comparison of three-pole and two-pole variants in the same series is available; those alternate MPNs share identical approvals, mounting, and 250 A ratings but differ in pole count, which affects branch width and coordination scope.

FAQ

Does the 3VA5225-6GC41-0AA0 support motor feeder protection? The fixed thermal/magnetic trip unit designation (FTAM) aligns with thermal-overload coordination in feeder or branch protection applications; confirm coordination with upstream protective devices against system fault level.

What mounting format does this breaker use? It is designed for DIN rail installation in standard distribution enclosures; verify enclosure depth and rail clearances for the four-pole frame.

Are the in-family alternates pin-compatible with the primary? The 3VA5225 series shares a common frame and mounting footprint across pole-count variants; however, any substitution requires the reader's own coordination and specification review.

Last updated: May 11, 2026