Skip to main content
3RA23268XB301AK6

3RA23268XB301AK6 Contactors (Electromechanical) | siemens

MPN3RA23268XB301AK6Compare · similar
Active · In production

3RA23268XB301AK6 (siemens) Contactors (Electromechanical). Series 3RA23; Package Bulk; Features Auxiliary Contacts. RFQ for MOQ and lead time.

PackagingBulk
Volume pricing1+ $414.87000
StockOut of Stock

Specifications

3RA23268XB301AK6 Technical Specifications - Column 1
ParameterValue
RoHSROHS3 Compliant
StatusActive
FeaturesAuxiliary Contacts
Coil Power77VA
Contact Form3PST-NO (3 Form A)
Termination StyleScrew Terminal
Must Operate Voltage96 VAC
Contact Rating (Current)25 A
3RA23268XB301AK6 Technical Specifications - Column 2
ParameterValue
Series3RA23
PackageBulk
MountingChassis Mount, DIN Rail
Coil Voltage120VAC
Switching Voltage690VAC - Max
Base Product Number3RA23268XB
Operating temperature25°C to 60°C

Product details

Siemens 3RA23268XB301AK6 Reversing Contactor

Family Context — S0 Frame 3-Pole Reversing Contactors

The 3RA23268XB prefix denotes the Siemens SIRIUS S0 reversing contactor series with auxiliary contacts and screw terminals. The "B" in position 12 designates screw-type load-side connection; the trailing "AK6" encodes the 120 VAC coil with bulk packaging. Reversing variants use mechanically interlocked contactors to swap two phases for motor-direction change. All units in this prefix share the same 25 A contact rating and chassis/DIN mounting footprint.

Contact Ratings and Coil Data (3RA23268XB301AK6)

ParameterValue
Contact Form3PST-NO (3 Form A)
Contact Rating25 A
Coil Voltage120 VAC
Coil Power77 VA
Must Operate Voltage96 VAC
Operating Temperature25°C ~ 60°C
MountingChassis Mount, DIN Rail
EncapsulationBulk
FeaturesAuxiliary Contacts included

The 77 VA inrush coil power is typical for AC-operated SIRIUS S0 contactors; the must-operate threshold of 96 VAC provides 80 % of nominal, consistent with IEC AC-3 utilization categories.

Comparison — Voltage and Terminal Variants

The reader must verify all specifications independently before specifying any alternate.

Spec3RA23268XB301AK6 (seed)3RA23268XB301AP63RA23268XB301AG23RA23268XB301BB4
Coil Voltage120VAC240VAC110VAC24VDC
Must Operate96 VAC192 VAC88 VAC
Coil Power77VA77VA77VA5.9W
Contact Rating25 A25 A25 A25 A
MountingChassis/DINChassis/DINChassis/DINChassis/DIN
Terminal StyleScrewScrewScrewScrew
Similarity1.01.01.0

Why similar — 3RA23268XB301AP6: Shares screw terminals, 77 VA AC coil, and 25 A contacts; differs only in coil voltage (240 VAC vs 120 VAC) and corresponding must-operate threshold (192 VAC).

Why similar — 3RA23268XB301AG2: Identical mechanical frame and current rating; 110 VAC coil at 88 VAC must-operate gives tighter voltage margin than the 120 VAC variant.

Why similar — 3RA23268XB301BB4: Same 25 A contact rating and mounting; DC coil at 5.9 W eliminates inrush VA and suits PLC-output or battery-backed systems, but requires different coil circuitry.

The spring-terminal variants (3RA302…) listed in the alternates share all electrical ratings but ship in box packaging with spring-clamp load connections instead of screw clamps.

Engineering Verification Checklist

  • Confirm supply voltage matches coil rating (120 VAC nominal; 96 VAC must-operate).
  • Verify load current ≤ 25 A and utilization category (AC-3 for motor starting, AC-1 for resistive).
  • Check that reversing interlocking mechanism is properly installed and mechanically engaged.
  • Confirm DIN rail or chassis mounting dimensions fit the enclosure or panel layout.
  • Verify auxiliary contact configuration matches control circuit requirements.
  • Confirm ambient temperature stays within 25°C–60°C range; derate if enclosure is ventilated.
  • Check that bulk packaging is acceptable; box-pack variants (suffixes AC2/AG2/AL2/AP6) ship individually.
  • Validate that screw-terminal wire gauge and torque settings follow Siemens terminal specifications.
  • Coordinate with motor-branch protection: contactor 25 A rating does not substitute for overload relay sizing.

Frequently asked questions

What does this page list for “Switching Voltage” on 3RA23268XB301AK6?

The storefront table shows **Switching Voltage**: 690VAC - Max. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Are there catalog alternates or second-source candidates for 3RA23268XB301AK6?

We screen on package, interface, headline electricals, and lifecycle cues visible here—not on marketing series names alone, and not as manufacturer interchange approval. Send target rails, loads, and clearance rules for a quote-backed short list.

Typical use cases for 3RA23268XB301AK6?

Application wording stays generic until your constraints are known; the part’s real job is defined by the parameters above.

Stock and scheduling for 3RA23268XB301AK6?

For 3RA23268XB301AK6, treat dates as indicative until confirmed on order. Ships quickly when in stock; otherwise lead time follows distributor or factory lots.

MOQ rules for 3RA23268XB301AK6 (3RA23268XB301AK6)?

Typical floor: Evaluation quantities are usually workable—confirm on RFQ.. Packaging and factory MOQs can differ; we reconcile on quote.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (5 parts) · columns 2+ sorted by Hub similarity to 3RA23268XB301AK6

Technical resources

Lifecycle: ActiveRoHS: ROHS3 Compliant