Active high reset — confirm polarity before layout
Active high reset is less common than active low. Most processors expect a low-true reset, so this part is a fit only when the target reset input is active high — or when you add an inverter.
Industrial temperature grade — indoor and outdoor telecom, not under-hood
Rated -40°C to 85°C, this part covers factory automation, base stations, outdoor telecom cabinets, and commercial HVAC.
Lifecycle and sourcing — active, no LTB risk
The MAX6868UK23D1S+T is listed as Active by the manufacturer and ROHS3 compliant. For volume production or a BOM freeze, this part is sourced through independent distribution and quoted to order against an RFQ.