Analog Devices MAX6820UT+T — Sensors & Transducers

MAX6820UT+T Sequencer IC - Analog Devices - SOT-23-6

MPNMAX6820UT+T
End of Life

Analog Devices MAX6820UT+T, Type Sequencer, 2-channel supervisor, 140 ms minimum reset timeout, adjustable/selectable voltage threshold, surface-mount SOT-23-6 package, -40°C to +125°C operating range.

$6.01Ref. price · indicative, final on quote
PackagingSOT-23-6
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX6820UT+T Technical Specifications
ParameterValue
TypeSequencer
Mounting typeSurface Mount
Voltage - thresholdAdjustable/Selectable
Number of voltages monitored2
Operating temperature-40°C ~ 125°C (TA)
PackageTape & Reel (TR); Cut Tape (CT)
Reset timeout140ms Minimum
CaseSOT-23-6

Product details

Two-channel sequencer in SOT-23-6

The MAX6820UT+T is a 2-channel voltage sequencer from Analog Devices, designed to control power-up and power-down order of two supply rails. It integrates a 140 ms minimum reset timeout to hold downstream logic in reset until all rails settle. The voltage threshold is adjustable/selectable, meaning the monitoring levels can be set per rail via external resistors or factory-programmed options, giving the board designer flexibility across different core and I/O voltages. Housed in a 6-pin SOT-23-6 package (supplier device package SOT-6), it occupies minimal PCB area — ideal for space-constrained industrial or automotive sensor modules.

Temperature range and environment

This suits it for outdoor telecom enclosures, engine-bay electronics, and factory-floor PLC I/O modules where the ambient can swing beyond commercial limits. For a sequencer, the wide temperature range is critical because the reset timeout and threshold accuracy must hold across the thermal cycle — a cold start at -40°C must still assert the minimum 140 ms reset pulse.

Lifecycle and compliance

It is fully ROHS3 compliant. Sourced through our distribution channel; quoted to order against BOM quantity. No stock-holding claim — confirm availability and current pricing at quote time via RFQ.

Frequently asked questions

What is the reset timeout of MAX6820UT+T?

The reset timeout is 140 ms minimum. This is the guaranteed pulse width the device asserts during power-up or a fault condition, ensuring downstream logic has time to initialize before the reset releases.

Does MAX6820UT+T have an adjustable threshold?

Yes, the voltage threshold is adjustable/selectable. This allows the designer to set the monitoring trip point for each of the two channels to match the specific supply rail voltage, using external resistor dividers or factory options.