Skip to main content
Analog Devices MAX6756UKTD0+ — Discrete Semiconductors

MAX6756UKTD0+ Simple Reset/Power-On Reset, AEC-Q100

MPNMAX6756UKTD0+
End of Life

Analog Devices MAX6756UKTD0+, Simple Reset/Power-On Reset, Active Low, Open Drain or Open Collector, 3.3V Threshold, SOT-23-5, -40°C to 125°C, AEC-Q100.

$1.53Ref. price · indicative, final on quote
PackagingSC-74A, SOT-753
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX6756UKTD0+ Technical Specifications
ParameterValue
TypeSimple Reset/Power-On Reset
SeriesAutomotive, AEC-Q100
Mounting typeSurface Mount
Voltage - threshold3.3V
Number of voltages monitored1
Operating temperature-40°C ~ 125°C (TA)
ResetActive Low
OutputOpen Drain or Open Collector
PackageBulk
Reset timeout20µs Typical
CaseSC-74A, SOT-753

Product details

Automotive-grade — what AEC-Q100 means for sourcing

AEC-Q100 qualification means this part has passed stress tests required for automotive tier-1 PPAP submissions. The lifecycle status is active, so there is no LTB or end-of-life risk for current designs.

Package and mounting

Housed in a SOT-23-5 surface-mount package, the MAX6756UKTD0+ takes minimal board area and is compatible with standard reflow profiles. The bulk shipping option means it arrives in a tube or tray, not tape-and-reel.

Frequently asked questions

Does MAX6756UKTD0+ have an active-low reset output?

Yes, the reset output is active low and open drain, so it pulls low when the monitored voltage drops below the threshold. An external pull-up resistor to the logic supply is required.

Is MAX6756UKTD0+ equivalent to MAX809?

The MAX809 is a pin-compatible supervisor with the same 3.3V threshold, active-low open-drain output, and SOT-23-5 package. The key difference is the reset timeout: the MAX6756UKTD0+ has a 20µs typical timeout, while the MAX809 typically has a 140ms minimum timeout. Choose the MAX809 if your system needs a longer reset hold time; the MAX6756UKTD0+ is better for fast recovery from brownout events.

What is the reset timeout of MAX6756UKTD0+?

The reset timeout is 20µs typical. This short timeout means the reset releases quickly once the supply returns above the threshold — suitable for applications where the supervisor must not delay system startup.

Is MAX6756UKTD0+ automotive qualified?

Yes, it is AEC-Q100 qualified, making it suitable for automotive applications that require PPAP documentation and extended reliability testing.