Skip to main content
Analog Devices MAX6378XR46+T — Power Management (PMIC / Gate Driver)

MAX6378XR46+T Voltage Detector, 4.63V Threshold, SC-70

MPNMAX6378XR46+T
End of Life

Analog Devices MAX6378XR46+T voltage detector, 4.63V threshold, active-low push-pull output, SC-70-3 surface-mount package, -40°C to +85°C operating range.

$2.71Ref. price · indicative, final on quote
PackagingSC-70, SOT-323
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX6378XR46+T Technical Specifications
ParameterValue
TypeVoltage Detector
Mounting typeSurface Mount
Voltage - threshold4.63V
Number of voltages monitored1
Operating temperature-40°C ~ 85°C (TA)
ResetActive Low
OutputPush-Pull, Totem Pole
PackageTape & Reel (TR); Cut Tape (CT)
CaseSC-70, SOT-323

Product details

Threshold voltage and reset behaviour

The MAX6378XR46+T is a single-channel voltage detector with a 4.63 V threshold — this is the voltage at the monitored rail where the device asserts a reset. For a 5 V supply rail, the threshold sits at roughly 92.6 % of nominal, which means it catches a brownout before the downstream logic enters an undefined state. The reset output is active-low with a push-pull, totem-pole stage. No external pull-up resistor is needed on the reset line — the output drives high when the supply is above the threshold and pulls low when it drops below. This saves a resistor on the board and keeps the reset signal rail-to-rail.

Package, temperature grade, and board fit

Housed in a SC-70-3 (SOT-323) package, the device occupies minimal board area — roughly 2.0 × 2.1 mm. The three-pin footprint (VCC, GND, RESET) routes easily on a two-layer board. The supplier device package is SC-70-3, which is the standard Analog Devices code for this leadframe. It covers most indoor and outdoor equipment that does not sit under a vehicle hood — telecom line cards, base station controllers, industrial PLCs, and HVAC controllers all fall within this band.

Lifecycle and compliance

ROHS3 compliant per the manufacturer's declaration, so it meets the current EU restriction levels for lead and other substances. The TR option is the standard reel for automated pick-and-place; CT is useful for prototyping or small-batch builds where a full reel is not justified.

Frequently asked questions

What package does MAX6378XR46+T use?

It uses the SC-70-3 (SOT-323) surface-mount package, a three-pin leadframe measuring approximately 2.0 × 2.1 mm. The pinout is VCC, GND, and RESET, making it straightforward to route on a standard PCB.