Analog Devices MAX6316LUK26DY+T — DC-DC Power Modules

MAX6316LUK26DY+T Simple Reset/Power-On Reset

MPNMAX6316LUK26DY+T
End of Life

Maxim Integrated MAX6316LUK26DY+T, Simple Reset/Power-On Reset, Active Low, Push-Pull Output, 2.63V Threshold, 1.12s Minimum Reset Timeout, SOT-23-5, -40°C to 125°C.

$5.46Ref. price · indicative, final on quote
PackagingSC-74A, SOT-753
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX6316LUK26DY+T Technical Specifications
ParameterValue
TypeSimple Reset/Power-On Reset
Mounting typeSurface Mount
Voltage - threshold2.63V
Number of voltages monitored1
Operating temperature-40°C ~ 125°C (TA)
ResetActive Low
OutputPush-Pull, Totem Pole
PackageTape & Reel (TR); Cut Tape (CT)
Reset timeout1.12s Minimum
CaseSC-74A, SOT-753

Product details

What this supervisor does on the board

The output is active-low push-pull, so it drives the reset pin directly without needing an external pull-up resistor. That saves a component on the BOM and keeps the layout clean. Rated for -40°C to 125°C ambient, this part handles industrial enclosures, outdoor telecom cabinets, and under-hood automotive modules where the temperature swings wide.

Package and mounting

Housed in a 5-pin SOT-23 package (SOT-753), it's a surface-mount part that fits tight layouts. The SOT-23-5 footprint is common across many supervisor ICs.

Lifecycle and sourcing

No end-of-life notice has been issued.

Frequently asked questions

What is the reset timeout of MAX6316LUK26DY+T?

The reset timeout is a minimum of 1.12s. After the supply rises above the threshold, the reset output stays low for at least that duration before releasing.

Is MAX6316LUK26DY+T compatible with 3.3V systems?

Yes. The 2.63V threshold is designed for 3.3V nominal supplies. It will assert reset when the 3.3V rail drops below 2.63V, which is a typical undervoltage condition.