Single-supply instrumentation amplifier in SOT-23-6
The MAX4460EUT+T: The rail-to-rail output stage maximizes dynamic range in low-voltage systems, while the 1 pA typical input bias current and 100 µV input offset voltage preserve accuracy in high-impedance sensor interfaces.
Parametric fit for precision signal chains
With a gain-bandwidth of 2.5 MHz and 0.5 V/µs slew rate, this amp supports signal bandwidths up to roughly 100 kHz at a gain of 25 before the GBW ceiling limits closed-loop response — adequate for bridge sensors, thermocouple amplifiers, and medical instrumentation front-ends. The 150 mA output drive per channel allows the amplifier to directly drive ADC inputs, reference buffers, or cable loads without an external buffer stage.
Lifecycle and compliance
The supplier device package is SOT-6.