Analog Devices MAX4173TEUT+T — Discrete Semiconductors

MAX4173TEUT+T Current Sense Amplifier, 1.7 MHz, SOT-23-6

MPNMAX4173TEUT+T
End of Life

Maxim Integrated MAX4173TEUT+T current-sense amplifier, single circuit, 1.7 MHz -3dB bandwidth, 420µA supply, SOT-23-6 package, Tape & Reel.

$4.04Ref. price · indicative, final on quote
PackagingSOT-23-6
StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX4173TEUT+T Technical Specifications
ParameterValue
Mounting typeSurface Mount
Amplifier typeCurrent Sense
Voltage - input offset300 µV
Voltage - supply span28 V
Current - supply420µA
Current - input bias700 µA
Operating temperature-40°C ~ 85°C
-3db bandwidth1.7 MHz
PackageTape & Reel (TR); Cut Tape (CT)
CaseSOT-23-6
Number of circuits1

Product details

Current-sense amplifier with 1.7 MHz bandwidth

The MAX4173TEUT+T is a single-circuit current-sense amplifier from Maxim Integrated, designed to measure load current by amplifying the voltage drop across an external shunt resistor. Its 1.7 MHz -3dB bandwidth supports fast transient detection in applications like motor-drive phase monitoring or battery-charger current loops, where the sense amplifier must track PWM ripple without significant phase lag.

Supply envelope and temperature grade

Operating from a 3 V to 28 V supply span, the part covers common rails from 3.3 V logic to 24 V industrial buses without an external regulator.

Input offset and bias for shunt accuracy

A 300 µV input offset voltage sets the minimum detectable shunt drop — for a 10 mΩ shunt, this translates to a 30 mA offset error at the output, which is acceptable for most overcurrent and load-monitoring thresholds. The 700 µA input bias current flows through the shunt and adds a small voltage error proportional to the shunt resistance; using a 1 mΩ shunt keeps this error below 1 µV, negligible relative to the offset.

ROHS3 compliance is confirmed, covering the full substance restriction list including the four phthalates — relevant for EU-market shipments and end-of-life recycling declarations.