Skip to main content
Analog Devices MAX41400ANL+ — Logic ICs

MAX41400ANL+ Instrumentation Amplifier, 28 kHz, 1 µV Offset

MPNMAX41400ANL+
End of Life

Analog Devices MAX41400ANL+, single instrumentation amplifier, 28 kHz -3dB bandwidth, 0.08 V/µs slew rate, 1 µV input offset, 65 µA supply, rail-to-rail output, 1.7 V to 3.6 V supply, 9-WLP package, -40°C to 125°C.

$2.63Ref. price · indicative, final on quote
Packaging9-XFBGA, WLBGA
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX41400ANL+ Technical Specifications
ParameterValue
Output typeRail-to-Rail
Mounting typeSurface Mount
Amplifier typeInstrumentation
Voltage - input offset1 µV
Voltage - supply span3.6 V
Current - supply65µA
Current - input bias10 pA
Operating temperature-40°C ~ 125°C
-3db bandwidth28 kHz
PackageStrip
Slew rate0.08V/µs
Case9-XFBGA, WLBGA
Number of circuits1

Product details

Precision instrumentation amp for low-power sensor front-ends

The Analog Devices MAX41400ANL+ is a single-supply instrumentation amplifier in a 9-WLP (1.26x1.23 mm) package, designed for precision sensor conditioning where low offset and low power are critical.

The -3 dB bandwidth of 28 kHz and slew rate of 0.08 V/µs tell you this is a precision part, not a high-speed amplifier. It handles DC and low-frequency AC signals cleanly — think 50/60 Hz line rejection, thermocouple outputs, or load-cell readings sampled at a few hundred hertz. The 10 pA input bias current preserves accuracy when driving from high-impedance sources like pH probes or pyroelectric sensors.

Package and assembly considerations

The 9-WLP (1.26x1.23 mm) wafer-level package saves board area but requires standard WLP handling: a clean, flat PCB surface, proper solder-paste stencil design, and reflow profile per the supplier's recommendations. The part ships in Strip form — verify the carrier format matches your pick-and-place feeder setup.

Frequently asked questions

What is the typical application of MAX41400ANL+?

This instrumentation amplifier is typically used in precision sensor front-ends — bridge sensors, thermocouples, strain gauges, and medical instrumentation — where low offset (1 µV), low bias current (10 pA), and low supply current (65 µA) are required.