Analog Devices MAX180CCQH+D — Discrete Semiconductors

MAX180CCQH+D Analog Devices DAS, 12-Bit, 100kSPS, 44-PLCC

MPNMAX180CCQH+D
End of Life

Analog Devices MAX180CCQH+D Data Acquisition System (DAS), 12-bit resolution, 100k samples per second, 8-channel, parallel interface, 44-PLCC package, 0°C to 70°C.

$43.87Ref. price · indicative, final on quote
Packaging44-LCC (J-Lead)
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX180CCQH+D Technical Specifications
ParameterValue
TypeData Acquisition System (DAS)
Mounting typeSurface Mount
Voltage5V, -12V, -15V
Voltage supply sourceAnalog and Digital
InterfaceParallel
Operating temperature0°C ~ 70°C
PackageTube
Case44-LCC (J-Lead)
Resolution12 b
Number of channels8
Sampling rate (Per second)100k

Product details

12-bit, 8-channel DAS in a 44-PLCC

The MAX180CCQH+D is a complete Data Acquisition System (DAS) from Analog Devices, integrating an 8-channel multiplexer, a 12-bit ADC, and a parallel interface in a single 44-PLCC package.

The DAS requires three supply rails: a +5 V digital supply plus -12 V and -15 V analog supplies, with separate analog and digital ground returns.

Housed in a 44-lead PLCC with J-bend leads (44-LCC, J-Lead), the MAX180CCQH+D occupies a 16.59 mm × 16.59 mm footprint. The J-lead profile allows socketed or soldered mounting; the PLCC footprint is a standard JEDEC outline, so existing PLCC-44 land patterns on a PCB accept this part without a layout change.

Analog Devices lists the MAX180CCQH+D as Active with ROHS3 compliance.

Frequently asked questions

What supply voltages does the MAX180CCQH+D require?

It requires three supply rails: +5 V for the digital section, and -12 V and -15 V for the analog section. Both analog and digital supplies are needed, with separate ground returns.