MAX1485EUB+ RS-422/RS-485 Transceiver, 250 kbps, Full Duplex

MPNMAX1485EUB+
End of Life

Analog Devices MAX1485EUB+ RS-422/RS-485 transceiver, full duplex, 250 kbps data rate, 4.75-5.25 V supply, 10-uMAX/uSOP package, -40°C to +85°C.

$5.62Ref. price · indicative, final on quote
Packaging10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

MAX1485EUB+ Technical Specifications
ParameterValue
TypeTransceiver
Mounting typeSurface Mount
Voltage4.75V ~ 5.25V
ProtocolRS422, RS485
Operating temperature-40°C ~ 85°C
DuplexFull
PackageTube
Data rate250kbps
Case10-TFSOP, 10-MSOP (0.118\", 3.00mm Width)
Receiver hysteresis70 mV
Number of drivers (Receivers)1/1

Product details

Full-duplex operation with one driver and one receiver on-chip means a single MAX1485EUB+ handles both transmit and receive pairs for a point-to-point RS-422 link or a multi-drop RS-485 bus where the driver is always enabled on the transmit side.

250 kbps data rate and 70 mV hysteresis — the bus-margin trade-off

The 250 kbps data rate is the maximum signaling speed across the RS-485 bus — at this rate the cable length is limited by the rise-time degradation, not the driver itself. For runs beyond 4000 feet, dropping to 115.2 kbps or lower keeps the eye open. The 70 mV receiver hysteresis provides 70 mV of noise margin on the differential bus — enough to reject common-mode noise from a nearby motor drive or switching supply without adding external filtering. A standard RS-485 receiver without hysteresis would chatter on a noisy idle bus.

A panel that sees direct sunlight on a summer day stays below 85°C with passive ventilation.

Frequently asked questions

What does the 70 mV receiver hysteresis mean on a noisy RS-485 bus?

The 70 mV hysteresis creates a dead band around the zero-crossing point of the differential signal — the receiver output does not toggle until the differential input exceeds +70 mV or falls below -70 mV. On a bus with 50 mV of common-mode noise from a nearby VFD, the receiver stays quiet instead of chattering at the PLC input.

What supply voltage does MAX1485EUB+ need?

A regulated 5 V rail from a buck converter or linear regulator works; an unregulated 5 V wall adapter that drops below 4.75 V under load will push the transceiver out of the guaranteed operating window.