CANbus transceiver for industrial control networks
The MAX13054ESA+: With a single driver and single receiver (1/1 configuration), it interfaces a CAN protocol controller to the differential bus lines in industrial automation, building management, and automotive aftermarket networks. The 70 mV receiver hysteresis filters noise on the bus, reducing false edge triggering in electrically noisy environments typical of factory floors.
8-SOIC footprint and PCB layout considerations
Surface-mount placement on a two-layer board is straightforward; the narrow 1.27 mm pin pitch allows routing the CANH/CANL differential pair with controlled impedance on the outer layer.
Active lifecycle and compliance documentation
The part is ROHS3 compliant, meeting the EU RoHS directive for lead-free soldering processes. No UL or IEC certification is cited in the available documentation.