Skip to main content
Analog Devices LTM2881MPY-5#PBF — Digital Isolators

LTM2881MPY-5#PBF ADI µModule RS422/RS485 Isolated

MPNLTM2881MPY-5#PBF
End of Life

Analog Devices µModule® LTM2881MPY-5#PBF, isolated RS422/RS485 transceiver, 20Mbps data rate, 2500Vrms magnetic isolation, integrated isolated power, 2-channel unidirectional, 32-BBGA, -55°C to 105°C.

$44.96Ref. price · indicative, final on quote
Packaging32-BBGA Module
StockContact for availability
MOQ1 pcs
  • 100% new & originalTraceable channels only — no refurbs, no pulls, no remarked parts.
  • Date & lot codes on quoteStated per line before you commit; label photos on request.
  • MSL-compliant ESD packingMoisture-sealed bags with indicator cards; reels photo-verified.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

LTM2881MPY-5#PBF Technical Specifications
ParameterValue
TypeRS422, RS485
SeriesµModule®
Channel typeUnidirectional
Mounting typeSurface Mount
Voltage4.5V ~ 5.5V
Voltage - isolation2500Vrms
Isolated powerYes
Operating temperature-55°C ~ 105°C
PackageTray
Data rate20Mbps
TechnologyMagnetic Coupling
Case32-BBGA Module
Number of channels2
Inputs - side 1/Side 21/1
Common mode transient immunity30kV/µs

Product details

Isolated RS422/RS485 transceiver with onboard DC-DC

The Analog Devices LTM2881MPY-5#PBF is a µModule isolated RS422/RS485 transceiver that integrates a magnetic coupling isolation barrier and an isolated DC-DC converter into a single 32-BBGA package. It delivers 2500Vrms of galvanic isolation between the bus-side and logic-side interfaces, eliminating the need for a separate isolated power module on the BOM.

What the 2500Vrms isolation and 30kV/µs CMTI mean for the bus

The 2500Vrms isolation rating provides reinforced protection for RS422/RS485 nodes in industrial environments where ground potential differences between equipment cabinets can exceed tens of volts. The 30kV/µs minimum common-mode transient immunity keeps the receiver from latching or bit-flipping when a motor drive or relay bank switches a high-voltage bus — a common failure point in factory-floor RS485 networks. The integrated isolated power (Yes) means the LTM2881MPY-5#PBF generates its own isolated-side supply rail internally, so the BOM does not require a separate DC-DC converter or transformer driver for the bus side.

Temperature range and deployment environment

The 32-BGA (15x11.25mm) package is surface-mount only; the module's BGA footprint requires the standard PCB land pattern and a reflow profile compatible with a 32-ball array.

Frequently asked questions

Does LTM2881MPY-5#PBF provide isolated power or require an external DC-DC converter?

It includes an integrated isolated power supply, so no external DC-DC converter is needed for the bus-side rail. The part generates its own isolated supply internally.

Can LTM2881MPY-5#PBF be used as a drop-in replacement for LTM2881MPY-5?

The #PBF suffix indicates ROHS3 compliance. The base LTM2881MPY-5 and this variant share the same functional ratings and package, so the #PBF version is the direct lead-free replacement for the non-PBF order code.