Device overview and key features
Timekeeping current is specified at 0.6µA to 0.7µA at 3V to 5V, which is the headline spec for battery-backed applications where every microamp matters. The industrial temperature range of -40°C to 85°C covers most embedded, telecom, and industrial equipment environments.
Lifecycle and sourcing status
The DS1342U+T&R is listed as Active on the manufacturer's lifecycle record and is ROHS3 compliant. This is not an NRND or EOL part — it remains a current-production device suitable for new designs and ongoing production. There is no last-time-buy window to track, and no PCN-driven urgency to secure inventory. As an active Maxim (now Analog Devices) RTC, the DS1342U+T&R is available through independent distribution channels.
I2C interface and integration notes
Communication is via a standard I2C 2-wire serial interface, which requires only SDA and SCL lines plus pull-up resistors. The DS1342U+T&R functions as an I2C slave device. The alarm feature generates an interrupt or can be polled; the square-wave output provides a programmable frequency reference without needing an external oscillator buffer.